background image

MANUALE  ISTRUZIONI             

OPERATOR’S HANDBOOK

MANUEL D’UTILISATION 

GEBRAUCHSANWEISUNG              

MANUAL DE ISTRUCCIONES

M O N O - J E T

Содержание Mono-Jet a

Страница 1: ...MANUALE ISTRUZIONI OPERATOR S HANDBOOK MANUEL D UTILISATION GEBRAUCHSANWEISUNG MANUAL DE ISTRUCCIONES MONO JET...

Страница 2: ...nce and cleaning 13 Summary of main cleaning and routine maintenance operations to be entrusted to pur posely trained surgery staff 14 Extraordinary maintenance operations to be entrusted to trained s...

Страница 3: ...02 Off IEC 417 5008 On IEC 417 5007 This appliance cannot work in the presence of an anaesthetic mixture inflammable with air of oxygen or of nitrogen protoxide Thermal motor protector Power output 0...

Страница 4: ...e box General features Installation The best position for the Mono Jet is near the dental unit precisely on the left of the chair close to the patient s feet ill A The 3b tube holder must be connected...

Страница 5: ...logical filter is available to filter the exhausted air ill C pag 4 Liquids heavier than air are collected on the bottom of the canister Draining is automatic the valve 6 ill D placed on the bottom of...

Страница 6: ...n for some seconds with open terminals aspirating air only so that hoses and manifold dry completely inside then cut off the power and pull out the filter To inspect the filter 9 lift up the pipe hold...

Страница 7: ...r compo nents subject to ageing hoses and seals should be replaced once a year The appliance must be tested periodi cally from the current safety regulations point of view Short circuit probes make su...

Страница 8: ...appliances and or the plants have been tampered with operations of any kind done by persons unfit and so unauthorised by the manufacturer For any application that is not included and described in this...

Страница 9: ...NTERR PORTELLO DOOR SWITCH S 1 INTERR GENERALE MASTER SWITCH TR 4VA T 1 BT 150 P 1 WL 02 C 2 47 mF C 1 0 1mF R 2 1K R 1 270 RS RELE SONDE PROBES RELAY RP RELE POMPA PUMP RELAY RM RELE MOTORE 14 06 96...

Страница 10: ...7 Gruppo aspirante Uni Jet 75 10 Manicotto portatubo secreti sul vaso portasecreti 11 Vaso portasecreti Maxi Canister 12 Pompa di drenaggio LEGEND OF COMPONENTS 1 On Off switch 2 Exhausted air silence...

Страница 11: ...58 FR 222 394 395 PENDING PATENT CATTANI IT M098A000019 IT M098A000119 EP 99830010 7 EP 99830011 5 EP 99830250 9 EP 00830491 7 IT M099A000165 US 09 624 182 6 A Via Natta 43122 Parma Italy 10 21 48 EST...

Отзывы: