background image

CC-TR100

 

13

12

 

CC-TR100

MODE-

1

 

or

 

MODE-

2

M

K

S/S/E

5. Tire circumference input

Enter the circumference of the tire of your bicycle in mm. 2096 mm (700 x 23 C) is preset as
the initial value. To change the value, use the MODE-2 button to increase the value, and use the
MODE-1 button to shift the digit selected.

Pressing the START/STOP/ENTER button and this is the last step in the initial set-up.

Adjustable range: 0100 to 3999 mm

NOTE:

• You can find your approximate tire size on the tire circumference chart on page 53.

• When a value outside the adjustable range is entered, an error indication appears on

the screen and you cannot select the value.

MODE-

1

MODE-

1

MODE-

2

S/S/E

6. Operation test

Test the functioning of the speed sensor, cadence sensor, and remote buttons with the main
unit attached to the receiver.

1. Raise the rear wheel and spin the tire, and make sure that the speed (Display 1) shows a

number greater than zero.

2. Turn the crank (backpedal) and make sure that the cadence (Display 3) shows a number

greater than zero.

OK

OK

NOTE:

If the screen remains at “0”, the relative positions of the magnets to the sensors
may be inappropriate. Follow the instructions given in “Installing the unit on your
bicycle”, on page 8.

3. Press the right and left remote buttons to check that you can operate the main unit with

them.

NOTE:

• If the button is not operable, it indicates that the main unit and/or the button

connector may not have been installed properly.

• In the initial setup, the MODE-1 and MODE-2 button functions have been speci-

fied. To change the settings, see “Defining remote button setting” on page 33.

Completion of initial set-up

When the setup is completed, set the date and time as described in “Configuring main unit”

on page 28.

Display-1

Rotate the rear wheel

Display-3

Rotate the crank arm

Changing a value

Select

Increases the value

Shifting the digit

3. Checking heart rate sensor ID

The heart rate sensor ID must be checked within five minutes after the formatting or restarting
operation.

Before performing an ID check, mount the main unit to the HR receiver.

NOTE:

Be sure to attach the main unit to the HR receiver. Signals from the heart rate sensor
cannot be received by the main unit alone.

Place the heart rate sensor approximately 20-80 cm from the main unit, and press the reset
button of the HR sensor for five seconds. The main unit will receive the signal from the heart
rate sensor, and will start checking the heart rate sensor ID. When the check is completed, the
ID number is displayed, followed by the next screen.

NOTE:

If the HR sensor is placed too close to the main unit (within 20 cm), the main unit
cannot receive the ID signal. If an ID check failed, change the distance, and reset the
heart rate sensor.

If “E” appears on Display-2, or a HR sensor ID check failed even at a proper distance,
the batteries may be dead. Replace the batteries of the heart rate sensor in the proce-
dure shown on page 48, and format (restart) the computer again.

Pressing the reset
button for five seconds

Select

Switch

For formatting

4. Selecting speed

unit

For restarting

Ready

4. Selecting speed unit

The default speed unit is “km/h.”

By pressing the MODE-1 or MODE-2 button, you can switch the unit between “K (km/h)” and
“M (miles/h).” Select the desired speed unit, and press the START/STOP/ENTER button. The
selected unit is now accepted, and the tire circumference screen appears.

Attach the main unit to
the receiver.

Содержание CC-TR100

Страница 1: ...HEART RATE CADENCE SPEED 2 8 25 Kuwazu Higashi Sumiyoshi ku OSAKA JAPAN 546 0041 ENGLISH 066600331 1 ...

Страница 2: ...ively and analyze their data It features wired speed and cadence and coded wireless heart rate for minimal interference with other external signals The computer can store up to 150 hours of computer downloadable data through the use of an optional download kit An optional power unit can also be purchased to record your torque and power output in watts Read this instruction manual thoroughly and un...

Страница 3: ...intenance 48 Spare accessories 49 Specifications 50 Registration 51 Registration card 51 Limited warranty 52 Tire circumference reference table 53 Registration Please register your TR100 to validate the warranty Refer to page 51 and make user registration About the manuals You can find the desired operating method or function description from the following three guides Basic installation and opera...

Страница 4: ...the main unit HR receiver or sensors Regularly check the positions of the magnet and the speed cadence sensors and make sure that they are securely mounted Do not use paint thinner or rubbing alcohol to clean the unit Do not subject the main unit HR receiver or sensors to strong impact take care also to prevent any of them from falling Heart rate sensor NOTE The heart rate transmitter has a maximu...

Страница 5: ...ate zone or cadence zone k Stored Data icon Lights up when the Stored Data function is turned on Flashes when the Stored Data cannot be performed l Wheel selection icon Indicates the wheel currently selected 1 In order to use this function the optional power unit must be installed 2 In order to use this function the optional download kit or power unit is required Display 4 Display 5 Screen display...

Страница 6: ... tie should be on the outside Inward side of the left crank arm J J M J G Left chain stay Installing the unit on your bicycle Follow steps 1 through 5 to mount the TR100 on your bicycle 5 1 2 3 1 Mount the bracket and HR receiver and then attach the main unit Mount the bracket E to the handlebar using the rubber pad K as a spacer Adjust the bracket to a position that provides good visibility and s...

Страница 7: ...n while pressing and holding the MENU button then release the RESTART button only When a beep sounds release the MENU button All items displayed After a few seconds have elapsed proceed to the heart rate sensor ID check Press the RESTART button All items displayed for 1 sec To heart rate sensor ID check Insulation sheet Close Open 5 Installing the remote buttons Select the positions to mount the r...

Страница 8: ... Completion of initial set up When the setup is completed set the date and time as described in Configuring main unit on page 28 Display 1 Rotate the rear wheel Display 3 Rotate the crank arm Changing a value Select Increases the value Shifting the digit 3 Checking heart rate sensor ID The heart rate sensor ID must be checked within five minutes after the formatting or restarting operation Before ...

Страница 9: ... sen sor is operating properly NOTE The heart rate sensor will start transmission approximately three seconds after it has stabilized Therefore a short time lag occurs before the icon begins to blink If the icon does not flash move the electrode pad little by little to find the optimum position for the heart rate reception Dryness may make measurement difficult Moistening the electrode pad allows ...

Страница 10: ...data on Display 5 Basic operations TR100 measures data when the bicycle starts moving You can view various data by pressing the MODE 1 and MODE 2 buttons You can also record lap data up to 199 laps or intervals Main computer functions The main screen has 5 windows which display different types of data Pressing the MODE 1 and the MODE 2 buttons change the displayed information as shown in the illus...

Страница 11: ...one simultaneously press the START STOP ENTER and MODE 1 buttons while the main measurement is displayed 3 Resetting the second measurement data To reset to zero all erasable data in the second measurement display only simultaneously press START STOP ENTER and MODE 1 while the second measurement icon is on Second measurement icon Lap Pressing the lap button during data measurement records lap time...

Страница 12: ...uring range 0 30 to 260 bpm M Maximum cadence Indicates the maximum cadence Measuring range 0 20 to 299 rpm Total Pedal Count Indicates the total pedal count When the count exceeds 9999 the x10 appears Measuring range 0 to 99990 rotations 2 Sec Display 1 and 4 Measured data NOTE You must wear the heart rate sensor to perform the heart rate measurement Current speed Indicates the current speed upda...

Страница 13: ...ap recording for about five seconds and the viewing of lap data 1 When the optional power unit is used power related data is displayed For details see the instruction manual for the power unit Display 5 TM 1 Elapsed time Indicates the elapsed time from the start of measurement to 1 10 second When it exceeds 10 hours 1 10 second is not displayed Measuring range 0 00 00 0 to 99 59 59 DST 1 Trip dist...

Страница 14: ...es are on and the value is out of your target zone An alarm will sound if the sound feature is turned on Heart rate zone alert Four heart rate zones can be set with range and target The range of each zone may overlap The zone value will flash when the target zones are on and the value is out of your target zone An alarm will also sound if the sound feature is turned on You can check the time in an...

Страница 15: ...page 39 MODE 2 MODE 1 Lap function Recording lap data Pressing the Lap button on the main display while riding records lap data Immedi ately after recording the lap number is displayed alternating between lap time average lap speed and split time lap distance NOTE Up to 199 laps can be recorded Lap times cannot be shorter than 5 seconds pressing the LAP button consecutively within 5 seconds will n...

Страница 16: ...t is not displayed as the de fault setting for Power Select is off To use these functions the optional power unit is required 4 To use the data files recorded in this menu the optional download kit or power unit is required Tire circumference input Auto mode Date Power select Cadence zone Heart rate zone Heart rate sensor ID Data file 4 Main display See page 29 See page 29 See page 30 See page 30 ...

Страница 17: ...g Minute setting Select Select Setting clock This function is used to set the clock and to choose between 12 and 24 hour modes Clock setting cannot be changed while the bicycle is in motion NOTE Press and hold the MODE 2 button to speed up the progression of numbers For the basic information on how to use the menu screen refer to page 28 Sound 1 Alarm sound setup An alarm will alert when the heart...

Страница 18: ...ART STOP ENTER LAP LAP Lt LIGHT Defining remote button setting menu screen Select Select For the basic information on how to use the menu screen refer to page 28 S S E S S E K K km h M mph MODE 1 or MODE 2 MODE 1 MODE 1 MODE 2 S S E S S E Manual odometer input menu screen Speed unit menu screen Manual odometer input Enter any numeric value as the odometer value Odo This allows the input of past da...

Страница 19: ...king selection impossible When a lower limit value greater than the upper limit value is entered the upper limit value is automatically adjusted to the value of the lower limit value plus one When a wrong upper limit value is entered the same adjustment is made First digit First digit Digit shift Third digit Second digit Second digit Digit shift Changing the lower limit value Changing the upper li...

Страница 20: ...pper limit value is entered the upper limit value is automatically adjusted to the value of the lower limit value plus one When a wrong upper limit value is entered the same adjustment is made The range of each zone may overlap Select First digit Changing the lower limit value Changing the upper limit value Third digit Second digit Digit shift First digit Second digit Third digit Digit shift Digit...

Страница 21: ... to Copy data For details see the instruction manual for the download kit Alternating data display Switch file End Memory consumption Recording interval Number of laps used in file Date of ride Ride time Ride start time Data file check screen File number For the basic information on how to use the menu screen refer to page 28 S S E S S E Heart rate sensor ID This function allows the ID signal tran...

Страница 22: ... 0 or 99 files have already been stored further data storage cannot be performed When the remaining memory indicates 0 while the data storage is in progress a data file is created at that point Measurement after that is switched to the regular measurement from the data storage When the regular measurement is performed even though the data storage is turned on the icon flashes Select recording inte...

Страница 23: ...S S E PC Link You can specify settings for connection of TR100 with your personal computer By using the optional download kit you can download and also upload data In addition with the power unit you can perform real time online measurement while connected to your personal computer NOTE For details see the instruction manuals for optional download kit and power unit PC Online Mount the main unit t...

Страница 24: ...erview of training with heart rate data For more complete information there are books and websites with more in depth information Generally the heart rate increases during exercise getting higher in conjunction with the in tensity of the workout Measuring the rate of your heart beat is a good indicator of the intensity of your workout By setting target HR heart rate zones and sticking to pre set e...

Страница 25: ...t be changed when measurement is in progress Make sure that the timer and or speed measurement are stopped Some menu screens require all data to be reset Trouble shooting If a malfunction occurs check the following before contacting CatEye or your retailer for repair or service Trouble on display Trouble Check Items Remedy Display motion becomes slower Is the surrounding temperature low below zero...

Страница 26: ...rmly close the battery cover NOTE After replacement be sure to perform the restarting operation page 11 check the HR sensor ID page 31 and set the date and time page 31 Heart rate sensor Battery life Approx 6 months when worn for 1 hour per day Using a coin or similar object turn and remove the battery cover on the surface of the heart rate sensor transmitter Replace used battery with a new lithiu...

Страница 27: ...p speed Split time Lap distance Second measurement Elapsed time Trip distance Average speed Control system 8 bit one chip microcomputer crystal oscillator Display system Liquid crystal display With white LED backlight Speed Cadence sensor signal detection system Noncontact magnetic sensor Heart rate sensor signal transmission and reception Electromagnetic induction radio system With the ID functio...

Страница 28: ...re Tire size Tire circumference reference table Tire size Limited warranty Applies only to Main unit HR receiver and Heart Rate Sensor Excluding depletion of batteries and wire damage Should the main unit HR receiver or Heart Rate Sensor fail under normal condition of use we will repair or replace it free of charge The warranty service will be performed directly by the CATEYE CO LTD When sending i...