5
UK
Cleaning, Care & Maintenance
• Always turn off and disconnect the appliance from the power supply before cleaning.
• Use soapy water and a damp cloth to clean the exterior of the appliance.
• Dry thoroughly after cleaning.
De-scaling
In hard water areas limescale can build up within the appliance after prolonged use. For best taste and
extended appliance life, de-scale it regularly. Installation of a water filtration system is also recommended.
To de-scale the appliance:
1. Pour a solution of de-scaler and water into the appliance.
2. Brush the interior gently with a soft bristled brush.
3. Discard the solution collected in the jug.
4. Fill the appliance with clean water and turn back On to flush out the system. Flush out the system
thoroughly to remove any de-scaler residue.
5. The appliance is now ready for use.
Note: Use a suitable de-scaler and always follow the instructions on the
packaging.
Caterlite recommend that this appliance is de-scaled every 3 months or more
frequently in hard water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.
Troubleshooting
Fault
Probable Cause
Solution
The unit is not working The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged Call Caterlite agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call Caterlite agent or qualified technician
Thermal cut-out switch has
activated
Reset Thermal cut-out switch (Page 4)
Power light comes on
but water does not
reach temperature
Thermostat fault
Call Caterlite agent or qualified technician
Heating time has
increased
Buildup of scale
De-scale the appliance
The tap is leaking
The tap has become loose
Tighten the tap handle
J709_J722_ML_A5_v6_20201223.indb 5
J709_J722_ML_A5_v6_20201223.indb 5
2020/12/23 14:16
2020/12/23 14:16