4.2 Checking the gas system
The gas system must be the subject of periodic checks:
-
Close all the taps on the cooker.
-
Open the regulator tap.
-
Check all the connections are sealed by using a leak detector or by applying soapy water.
WARNING
Do not modify the LPG system of the boat. Installation, modifications and maintenance must be
carried out by a competent person. Have the system checked at regular intervals or at the intervals
required by national regulations.
Never use the gas system in the event of a leak.
Any repairs or modifications to the gas system must be carried out by a qualified person.
Flexible hoses must be:
-
Regularly checked, at least once a year,
-
Replaced if the expiry date printed on the hose has passed,
-
Replaced five years after the date of manufacture of the hose which may be marked on it,
-
Replaced in the event of signs of wear or cracks.
-
Check the evacuation ducting at least once a year.
-
Replace in the event of wear or cracks.
CAUTION
Do not use any solutions containing ammonia.
Do not smoke or use a naked flame when changing LPG gas bottles
DANGER
Never use a naked flame to attempt to detect leaks.