background image

 

18 

 Production Automation    

PCI Test I/F Package   

 

 

 

 

Hot Swap up to 2 UUT boards on an enclosed system 

 

Low cost, easy to replace Connectors  

 

Designed to be used with the PCIBX.  

 

May be used in test environments where it is not desirable to leave the PC Chassis open.  

 

LEDs provide visual indication of UUT power. 

 

Easy automation of the power up and power down cycles, through software control. 

 

Minimizes the extender board connector wear-out. 

 

This fixture is designed for a 6" high PC Chassis, the user must cut a hole in the top cover of the chassis. This fixture 
will connect to the installed PCIBX extenders, via a provided adapter PCIMM. After the fixture is installed the PC cover 
may be installed again. 

 
 
 

 

 
 
 
 
 
 
 

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PCIBX32-X

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...n 2 3 February2003 90 Great Oaks Blvd Suite 102 San Jose CA 95119 Tel 408 365 3846 Fax 408 365 3847 Email support catalyst ent com www getcatalyst com P N 400 0062 003 Artisan Technology Group Quality...

Страница 3: ...X32 3 PCIBX64 5 PCIBX64 3 7 MECHANICAL DIMENSIONS 7 REGISTERS 8 PROGRAMMING GUIDE 10 READ WRITE ROUTINES 14 EXAMPLE ON OFF SOFTWARE CONTROL 15 SAMPLE CODE 15 AC CHARACTERISTICS 15 HOT SWAPPING UTILITI...

Страница 4: ...ue SW commands or continue to use the switch to turn the power to the extender Off and back On In addition to Hot Swapping the main voltages and signals the PCIBX cards have the following features 1 S...

Страница 5: ...iguration registers This software is available free of charge For an overview of these software packages see the Hot Swapping Utilities section of this manual ON OFF To insert or remove any Unit Under...

Страница 6: ...ing Guide CURRENT LIMIT CIRCUITRY Red LEDs when illuminated indicate a short or a very low voltage Green LEDs when illuminated indicate voltages at their corresponding outputs 5V 12V 3 3Vare electroni...

Страница 7: ...rnal supply The following diagram indicates the interconnection of the Unit Under Test voltages to the bus voltages and the external voltages 5VE ON OFF 5V out to UUT Circuitry VIO to UUT JP5 JP10 ON...

Страница 8: ...ltage condition D15 12V has a short or low voltage condition D14 3 3V has a short or low voltage condition D16 5V has a short or low voltage condition 5V 3 3 V Translation PCIBX is capable of allowing...

Страница 9: ...5V source is from the external input JP6 Installed 12V source is from the system Not Installed 12V source is from the external input JP7 Installed 1 2 3 3V to UUT is from On board source Installed 2 3...

Страница 10: ...gation Delay Less than 500 Pico seconds from the PC bus to the UUT The switch propagation delay is rated at only 250 Pico seconds On Off Controls SPST switch on board or the system parallel port Outpu...

Страница 11: ...1 Enables power switches to be programmed PCI UUT Voltages 64 e4 W R D0 0 On 5V 12V 12V and 3 3V D0 1 Off After turning the extender on and before start using the UUT or starting any test program a w...

Страница 12: ...tected D2 1 32 operation established PCIBX64 Only D3 0 33 MHz enabled slot D3 1 66 MHz enabled slot D4 0 DUT not fully asserted D4 1 DUT asserted 32 64 status bit clear 77 f7 W 0x0 To clear status reg...

Страница 13: ...0 DUT not fully asserted D4 1 DUT asserted 4 Clear 32 64 bit status Use the set Address routine to set address DUT 1 0x77 DUT 2 0xf7 Use write routine to write 0x0 5 To Turn on or off any Voltages Gl...

Страница 14: ...e turning any voltages on or off Use the Set Address routine to set address DUT 1 0x66 DUT2 0xe6 use write routine to write 0x0 11 3 3V Aux Down Use the Set Address routine to set address DUT 1 0x66 D...

Страница 15: ...dress routine to set address DUT 1 0x67 DUT2 0xe7 use write routine to write D 7 0 Signal to Convert Read 0X08 2 5V Reference 0X09 12V UUT 0X0A 5V UUT 0X0B 3 3V UUT 0X0C 5V Aux 0X0D Current 5V 0X0E Cu...

Страница 16: ...tages and currents in Volts and Amps except 12V voltage Read Data decimal 5 75 2 5 4096 for 12V voltage only 15 Select 5V ramp Use the Set Address routine to set address DUT 1 0x7c DUT2 0xfc use write...

Страница 17: ...I card Address register outp 0x37a 0xd6 Wait 100 us minimum Reset the AS and DS signals outp 0x37a 0xde Set the port to read mode outp 0x37a 0xff Read Register and display I inp 0x378 Reset the AS and...

Страница 18: ...6 strobe address o 37a de return strobe o 378 00 set data to turn the board on o 37a dc strobe data o 37a de return strobe Commands to turn the PCIBXOFF o 37a de return strobe o 378 64 set address for...

Страница 19: ...se refer to the PCIUD document located on our website http www getcatalyst comon the Documents page 2 PCIUW This Windows program allows the users of Windows 95 98 ME and Windows NT 2000 XP to read sav...

Страница 20: ...operly by executing your application 5 If the UUT is working properly you can proceed using the software provided in this package please see the section on Operating Instructions for PCIUW or PCIUD 6...

Страница 21: ...UUT power Easy automation of the power up and power down cycles through software control Minimizes the extender board connector wear out This fixture is designed for a 6 high PC Chassis the user must...

Страница 22: ...oller or other Bridge Chips If it does install a 22 uF Capacitor between Pin 3 of U13 and GND This capacitor will slow down the time between when the 5V goes high and the time the Chip enable is drive...

Страница 23: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...