DANGER!

Risk of Electrocution

All electrical connections must be performed by a qualified licensed electrician in accordance with the National Electric Code 

(NEC) following state and local electrical codes in effect at the time of the installation. 

•  Connecting the spa to an improperly wired circuit will eliminate many of the spa’s built in safety features which may result 

in fire, electrocution, or other risk of injury. Damages to the spa which are the result of improper wiring are not covered 

under the manufacturer’s warranty and will terminate all listings from independent listing agencies. 

•  The electrical supply for your spa must be housed in a weatherproof junction box and include a suitably rated switch and 

Ground Fault Circuit Interrupter

 

between the main service entrance and the spa to open all ungrounded supply conductors 

in compliance with Section 422-20 of the National Electrical Code/USA, ANSI/NFPA/70 and in compliance with independent 

listing agencies. This might be used as a shut off switch, and must be installed so that it is accessible to the spa occupants, 

but not within 5 feet (1.5m) of the spa. 

•  The wiring specifications in this manual are for standard installations where the main power supply is within 40 feet of the 

spa. If the main power supply is more than 40 feet away, the electrician must make appropriate modifications. 

•  The electrical instructions and diagrams contained in this manual and inside the spa control box are included as a guideline 

for the licensed electrician installing the electrical connections and vary by model. Please refer to the wiring diagram inside 

the spa control box for model specific connection instructions. All wiring connections must be watertight.

•  All connections must be made using copper conductors only. Do not use aluminum wire. Connection wires, circuit 

breakers, and/or fuses, must all be sized to accommodate the Total Ampere load.

•  Never turn power on to the spa when it is not filled with water.

 

DO NOT connect power to the empty spa.  When power 

is supplied to the spa, it automatically activates critical components within the spa, such as the pumps, controls and 

the heating. If power is supplied to the components before it is filled with water, the components may be damaged 

instantly. Damage that occurs to the spa  because power was supplied before it is filled with water is not covered by the 

manufacturer’s warranty.

•  Prior to performing any service, turn OFF all primary electrical equipment at the main circuit breaker or disconnect panel.

•  Your spa must be permanently connected (hard wired) to a power supply that is protected by a Ground Fault Circuit 

Interrupter (GFCI). Power supplied to your spa must be a dedicated circuit with no other appliances, lighting, or other 

electronic components powered by the circuit.

•  Do not permit any electrical appliances like lights, telephones, mP3 players, radios or televisions within five feet (1.5m) of 

the spa unless they were built in by the manufacturer. Failure to maintain a safe distance may result in death or serious 

injury from electrocution if the appliance should fall into the spa.

•  Do not use head phones while using the spa

•  All metal components or accessories that are permanently installed, like handrails, ladders, drains and hardware that are 

within 5 feet (1.5 m) of the spa must be bonded to the equipment grounding bus with copper conductors no smaller than 

No. 6 AWG. 

 

WIRING REQUIREMENTS FOR 240V SPAS

•  The minimum wire size for 40 and 50 amp systems is # 6/3 c/w ground (6 gauge/4 conductor) if the main power supply 

is within 40 feet of the spa. If the main power supply not within 40 feet, your electrician should make the appropriate 

modifications.

•  The spa must have dedicated 240V service from the main power supply.

 

Do not attempt to share service with other 

appliances. Use only a class ‘A’ double-pole Ground Fault Circuit Interrupter (GFCI).

•  To access the spa controls, remove the cabinet panel and store it safely. Do not replace the access panel until the spa is 

filled with water and you are sure it is operating properly.

Number of 

Pumps

Voltage

Breaker

Connection

1

120V

20 amp

Plug In

1

240V

40 amp

Hard Wired

2

240V

50 amp

Hard Wired

3

240V

50 amp

Hard Wired

Electrical Service Requirements

Electrical Requirements and Recommendations

240V ELECTRICAL INSTALLATION

N

ever

 

turN

 

the

 GFCI ON 

beFOre

 

FIllING

 

yOur

 

spa

 

wIth

 

water

!

a

lways

 

turN

 

the

 GFCI OFF 

beFOre

 

servICING

 

Or

 

draINING

 

yOur

 

spa

!

Содержание Armstrong

Страница 1: ...1 S p a s Catalina Since 1977 O W N E R S M A N U A L L U X U R Y C O L L E C T I O N...

Страница 2: ...2...

Страница 3: ...stallation Recommendations 6 Electrical Requirements and Recommendations 8 240VInstallation 8 120V Installation 9 Getting to Know Your Spa Electronic components 10 Plumbing components 11 Filling Your...

Страница 4: ...ally sensitive to hot water Make sure child resistant locks on the spa cover are engaged after use The spa cover that comes with your spa meets the ATSM F1346 91 Standard for Safety Covers However use...

Страница 5: ...k of injury exercise care when entering and exiting the spa Give children instructions about how to safely enter and exit the spa Remove all jewelry and put long hair in a bathing cap or hair tie befo...

Страница 6: ...contact your local gas electric water and cable companies to be sure there are no underground lines in the site you have chosen For best results site preparation should begin with digging an area tha...

Страница 7: ...r meeting the towing service at the destination terminal to inspect the spa and allow the carrier to move the spa onto the flat bed This is typically an efficient way to coordinate a convenient delive...

Страница 8: ...h as the pumps controls and the heating If power is supplied to the components before it is filled with water the components may be damaged instantly Damage that occurs to the spa because power was su...

Страница 9: ...rge protector Low voltage may cause damage that is not covered under the manufacturer s warranty Do not unplug this spa under normal conditions Your spa is engineered for optimal energy efficiency and...

Страница 10: ...disabled until they are completed The Spa Heater warms the water Once your temperature settings have been programmed your water temperature will be maintained automatically When the water temperature...

Страница 11: ...tricted which can damage your spa Keep hair clothing and children away from the suction drains when using the spa It is important to check them on a regular basis making sure they are good condition D...

Страница 12: ...is not filled properly or from improper water levels is not covered under the manufacturer s warranty 7 Remove the garden hose and turn the water off 8 Check the drain valve to be sure no water is le...

Страница 13: ...and for every spa user Your water chemistry changes constantly When the water in your spa evaporates dissolved solids like calcium salt and metal remain they do not evaporate with the water Adding mor...

Страница 14: ...Alkalinity Up Step 2 Balancing Calcium Hardness CH The recommended calcium hardness CH level for your spa is 150 250 ppm Calcium Hardness is a measurement of the total amount of dissolved calcium in t...

Страница 15: ...draining and refilling the spa will not kill the algae It will be necessary for you to decontaminate the spa before it can be used safely Warning Risk of Chemical Reaction and Noxious Fumes During th...

Страница 16: ...r put your filter in the dishwasher Never put a dry filter in the filter housing Replacement Filter Cartridges Deep cleaning dirty filters is time consuming requires the use of additional chemicals an...

Страница 17: ...n the back of the jet is damaged it should be replaced Replacement jets are available from your local dealer Caring for the Lights The lense cover over the underwater light is permanently installed Do...

Страница 18: ...hose over each suction fitting for 30 seconds to blow out water in the suction lines 6 Open all of the jets Moving in a clockwise direction and starting at the top of each seat working down blow each...

Страница 19: ...wim wear Water has Bad Smell Excessive Organic Matter Bacteria Growth Add Shock Improperly Sanitized Add Sanitizer Low pH Adjust pH Chloramines Add Oxidizing Shock Smells Musty Bacteria Growth Add Sho...

Страница 20: ...ure Normal function of spa Operating Mode Check to be sure the spa is not in Economy Mode Temperature Setting Check LED display to see if Heater Icon is illuminated Breaker s off Reset GFCI and Main B...

Страница 21: ...ust be followed Damage caused by failure to have a properly leveled and supported foundation under the spa is not covered under warranty The MANUFACTURER does not warrant against problems associated w...

Страница 22: ...er documentation will be delayed It is the responsibility of the spa owner to ensure that the spa is accessible for repairs MANUFACTURER is not responsible for any cost associated with making spa acce...

Страница 23: ...ent the risk of death by electrocution or fire may be disabled and the electronic components in your spa may be damaged beyond repair Damage to your spa that occurs because it wasn t connected properl...

Страница 24: ...24 Eaton Brand 50 AMP GFCI Square D 50 AMP GFCI...

Отзывы: