HU-33
GENERAL DIMENSIONS OF PRODUCT AND CABINET
(*) Through the hole diameter
60
mm
it is
imperative
to
pass the electric cable of the oven.
CONNECTING TO THE ELECTRIC MAINS
•
The oven is provided with a three
-
pole power cable with free terminals.
•
If the oven
is
connected permanently
to
the mains,
install a
device
ensuring
disconnection from the mains,
with a contact opening distance (of at least 3 mm) that allows complete disconnection in the conditions of
overvoltage category III. Check that:
a) The plug and socket are suitable for a current of 16°
b) Both
are
within easy reach and placed
so
that
no
live part can
be
accessed while plugging
in or
unplugging
c) The plug can be inserted without difficulty
d) Once the plug has been inserted, the oven does not rest on it when it is installed in the cabinet
e) The terminals of two appliances
are not
connected to the same plug
f) If changing the power cable,
use one
with 3
x
1.5
mm specifications
2
type H05VV
-
F or H05RR
-F
g)
It is essential
that the coupling polarities of the
free terminals
are
respected (Brown
=
Live;
Blue
= Neutral; Yellow
-
Green = Earth).
N.B. Make sure
the characteristics of your household
electrical power supply (voltage, maximum power
and current) are compatible with those of your
new oven.
60 mm(*)
60 mm(*)
895 mm
480 mm
m
m
47
4
854 mm
546 mm
21.5 mm
860 mm
475 mm-477 mm
min.550 mm
max.560 mm
860 mm
min.550 mm
max560 mm
m
m
77
4-
m
m
57
4
500 mm
500 mm
35 mm
35 mm
225 mm
225 mm
520 mm
520 mm
40 mm
40 mm
L
N
EN-16
Содержание CMD 9208 BK
Страница 1: ...CMD 9208 BK HU Haszn lati s kezel si utas t sok EN Use and handling instructions...
Страница 2: ...HU 1...