Operator's Manual
HPS09 Pellet Stove
Check for parts online at
www.castlestoves.com
or call 800-345-6007 M-F 8-5 CST
14
vent termination clearances
clearance
4 feet
Clearance below or beside any door or
window that opens.
1 foot
Clearance above any door or window that
opens.
3 feet
Clearance from any adjacent building.
7 feet
Clearance from any adjacent public
walkways.
2 feet
Clearance above any grass, plants, or other
combustible materials.
3 feet
Clearance from any forced air intake of any
appliance.
2 feet
Clearance below eaves or overhang.
1 foot
Clearance horizontally from combustible
wall.
3 feet
Clearance above the roof.
2 feet
Clearance above the highest point on the
roof within 10 feet.
ventIng InStallatIon exampleS
Figure 9: Straight Installation—inside vertical rise, horizontal
termination
Figure 8: Straight Installation--outside vertical rise, through wall
installation
IntaKe & exhauSt poSItIonS
12”
10-½”
7-⅜”
4-⅜”
Figure 7: Intake and exhaust positions