sPecifications

model number

hPs09

BTU/hour input (1)

40,000 max

Heating Capacity (2)

1,700 Sq. Ft. 

Electrical Rating (3)

110-120 volts, 4.5 Amp, 

60 Hz

Power Consumption

520 Watts ignition,

200 Watts operating

Fuel Storage Capacity

40 lbs.

Flue Size (4)

3 in.

Width

24.4 in.

Height

32.1 in.

depth

23.6 in.

Weight

287 lbs.

(1) Heat output will vary, depending on the brand, type 

and quality of fuel and the moisture content. Consult 
your dealer for best results. 

(2) Based on post 1982 home construction, requiring 35 

BTU/Hr. per Sq. Ft.

(3) Install per NFPA 70 and follow all state and local 

codes, contact licensed electrical contractor for 
assistance.

(4) Install per NFPA 211 and follow all state and local 

codes, contact licensed installers for assistance.

Listing label: 

 
Tested to the following standards:  UL1482, ASTM E1509, 
ULC/ORD-C1482-M1990

glass sPecifications

This stove is equipped with 5 mm ceramic glass. Replace 
glass only with Castle Pellet Stoves ceramic glass.  Call 
your Servicing Dealer or Castle Stoves at 1-800-345-6007 
for replacement parts.

unPacking

Your Castle HPS09 will come fully assembled.  Remove 
all packing material and tape from the inside of the 
firebox.  Remove any tape on the outside of the glass.  
Open the hopper, remove all packing material and 
power cord.

NOTE:  MakE surE ThE hOppEr is frEE Of all 

fOrEiGN MaTTEr bEfOrE filliNG wiTh fuEl.  

fOrEiGN MaTErial will causE auGEr jaMs 

aNd will vOid sTOvE warraNTy.

 Caution

this installation must conform with 

local codes. in the absence of local 

codes you must comPly with astm 

e1509, (um) 84-hud, ulc/ord-c-1482.
castle Pellet stoves, manufacturer of 

this aPPliance, reserves the right to 

alter its Products and/or their sPeci-

fications  without notice.

Содержание HPS09

Страница 1: ...eater Failure to follow these in structions could result in property damage bodily injury or even death Caution Contact local building or fire officials about re strictions and installa tion inspection require ments for your area CAUTION Important operating and maintenance instruc tions included Save these instructions andLeavethismanualwith any party responsible for use and operation DO NOT DISCA...

Страница 2: ...over firing Reduce feed rate Overfiring will void the warranty Complywithallminimumclearances to combustibles as specified Failure to comply may cause a house fire Caution Tested and approved for pellet fuel Burning any other type of fuel voids warranty Caution Check building codes priorto installa tion Contact the regulating author ity prior to installation to determine the need for a permit Inst...

Страница 3: ...___________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ ____________________________...

Страница 4: ...rotection Requirements 8 Clearance to Combustibles 9 Venting 10 Type of Vent 10 Pellet Vent Installation 10 Vent Termination Clearances 11 Venting Installation Examples 11 Outside Air Connection 12 Mobile Home 12 UNDERSTANDING YOUR STOVE 12 Operating Stove 13 Start Up Procedures 13 Shut Down Procedure 14 Maintenance 15 End of Season Shut Down 15 TROUBLESHOOTING REPAIR 16 Ordering Replacement Parts...

Страница 5: ...easy reference Fill out and mail the registration card located in the parts packet or register online at www castlepelletstoves com Warranty is valid only if the completed registration is received by Ardisam Inc within 30 days of purchase OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Province Zip Code Postal Code Model Number Serial Number Date of Purchase Notes SERVICE DATE SERVICE ...

Страница 6: ... and recommenda tions outlined here and inserted throughout the text Anyone who uses this tiller must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safety Read and followallinstructionsinthismanualbefore attempting to operate this equipment Warning WARNING INDICATES a serious injury or...

Страница 7: ...let Stoves which are burned in this stove will void the warranty DO NOT route power cord in high traffic areas A power surge protector plugged into a grounded 110 volt power source is required DO NOT install a flue damper in the exhaust venting system of this unit DONOTconnectthisunittoachimneyflueservicing another appliance Do not install in a sleeping room DO NOT connect to any air distribution ...

Страница 8: ...will result in a total loss of heat Do not leave hopper door open while unat tended caution Installation and repair of this pellet stove should be done by a qualified ser vice person The appliance should be in spected before use and at least once a year by a qualified service person It is imperative that the control compart ments fire box and the circulating air passageways ofthe stove be kept cle...

Страница 9: ... periodically See Normal Care Maintenance section for cleaning procedure Due to the nature of pellet fuels this stove will require attention periodically Regular cleaning is an important part of burning pellet fuel PELLETS This pellet stove is designed and approved to burn wood pellets that comply with pellet fuels industry standards Minimum of 40 lbs density per cubic feet 1 4 to 5 16 in diameter...

Страница 10: ...es contact licensed installers for assistance Listing label Tested to the following standards UL1482 ASTM E1509 ULC ORD C1482 M1990 GLASS SPECIFICATIONS This stove is equipped with 5 mm ceramic glass Replace glass only with Castle Pellet Stoves ceramic glass Call your Servicing Dealer or Castle Stoves at 1 800 345 6007 for replacement parts UNPACKING Your Castle HPS09 will come fully assembled Rem...

Страница 11: ... When stove is vented straight through the wall and the clean out t vent is on the exterior of the home the minimum clearance is 3 from the back of the stove to the edge of floor protector See figure 2 The minimum floor protector material is 24 GA sheet metal Figure 1 Figure 2 6 6 6 6 4 4 4 4 2 3 Figures 1 and 2 Pellet stove floor pad clearnances Warning READ THIS ENTIRE MANUAL BEFORE YOU INSTALL ...

Страница 12: ...en interior vent is installed vertically the clearance to the back wall is determined by the vent size used Install vent at clearance specified by the vent manufacturer Take into consideration any upward turning elbows or tees 5 5 Figure 3 Straight installation through wall Figure 4 Corner installation through the wall vents Figure 5 Straight installation interior vertical vents Figure 6 Corner in...

Страница 13: ...appliance shutdown The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system Total length of horizontal vent must not exceed 10 feet The maximum recommended vertical venting height is 18 feet All joints for pellet vent are required to be fastened with at least three screws and all pellet vent connections must be sealed accor...

Страница 14: ...t Clearance above any grass plants or other combustible materials 3 feet Clearance from any forced air intake of any appliance 2 feet Clearance below eaves or overhang 1 foot Clearance horizontally from combustible wall 3 feet Clearance above the roof 2 feet Clearance above the highest point on the roof within 10 feet VENTING INSTALLATION EXAMPLES Figure 9 Straight Installation inside vertical ris...

Страница 15: ...codes may apply UNDERSTANDING YOUR STOVE Your Castle pellet stove utilizes a vertical auger fuel feed system that is operated by a microprocessor controlled digital circuit board The digital circuit board allows the vertical auger fuel system to run in a timer based non continuous cycle this cycling allows the auger to run for a predetermined amount of time The auger pushes pellets up a chute loca...

Страница 16: ... fuel the auger will not be primed with pellets This may cause the automatic ignition to time out and the unit will shut down Pressing the button on the control pad again will restart the startup sequence and the stove should start properly Once a consistent flame has been established you can adjust the heat range to your desired setting low medium or high This is done by pressing the button on th...

Страница 17: ...uminates when the main power switch is on See figure 10 4 Fault Indicator Illuminates when stove is overtemped or if there is loss of fire during startup or during normal operation See troubleshooting section 5 Auto Ignition Indicator Illuminates when igniter is operating 6 Fuel Feed Indicator Illuminates when the feed auger is operating 7 Exhaust Blower Indicator Illuminates when exhaust blower i...

Страница 18: ... materials If ashes are disposed of by burial or otherwise locally dispersed they should be retained in the closed container until all cinders have bee thoroughly cooled See figure 16 Soot and Fly ash Formation and Need for Removal The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases Incomp...

Страница 19: ...ad to answer any questions you have or help you find suitable assistance To order parts or inquire about warranty call or write us at the address found below ORDERING REPLACEMENT PARTS Parts can be obtained from the store where the stove was purchased or direct from the factory To order from the factory call write or e mail to Ardisam Inc 1160 Eighth Avenue Cumberland Wisconsin 54829 1 800 345 600...

Страница 20: ...le Overtemp Allow stove to cool restart and check room air fan is operating Check for exhaust fume obstructions Problem CAUSE Solution Fuel not feeding Main door not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negative pressure in fire chamber Check door seals Check viewing glass seals Clean venti...

Страница 21: ..._____________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ __________________________________________________...

Страница 22: ... for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 Viewing Door Detail 39 41 42 43 44 48 45 47 46 40 49 32A 32 32B ...

Страница 23: ...heat shield 24 720276 rtd mount 25 720106 rtd overtemp sensor 92 degree Celsius 26 720277 side wire channel 27 720278 hopper support 28 720120 auger housing 29 720222 lower cover plate auger 30 720223 auger motor mount plate 31 720107 gearmotor KEY PART DESCRIPTION 32 720219 weld assembly auger 32a 720220 auger bearing lower 32b 720221 auger bearing upper 33 720279 bracket vacuum switch 34 720108 ...

Страница 24: ...for parts online at www castlestoves com or call 800 345 6007 M F 8 5 Castle Stoves Division of Ardisam Inc 1160 8th Avenue PO Box 666 Cumberland WI 54829 800 345 6007 Fax 715 822 2223 Email info ardisam com ...

Отзывы: