24
25
Operating faults
• When the lance switch is actuated, the pump does not operate:
1. Check that the side switch is not set to "Off"
2. Check the battery connections
3. If the issue continues, do not persist, remove the battery and have
its charge checked by an authorised support centre.
4. If the battery is charged and the issue continues, contact Casotti or the reference
dealer
• The motor runs smoothly but no liquid is dispensed from the tank:
1. Check that the pump suction filter and the nozzle filter are clean.
2. Check that the solenoid valve on the lance is operating
• The side switch is set to “timed” but no liquid is sprayed when the
lance switch is pressed
1.
Check that the solenoid valve on the lance is operating
2. Move the switch to "continuous" to bypass the timer.
If SparaMosca operates normally, the timer or the switch may be damaged.
In this case, contact Casotti or the reference dealer.
If there are other faults, contact Casotti or the reference dealer.