background image

22

23

Maintenance   

Washing 

Firstly, recover any residues of pesticides into a suitable container.

Only use clean and clear water to clean the tank and the entire circuit.

Rinse thoroughly, flushing clean water while the pump is operating, 

recovering the liquid as per current regulations.

Check the nozzle clogging and wear conditions. 

Battery 

Recharge the accumulator after each use of the machine, 

in order to maintain its efficiency over time.

In the event of long periods of inactivity of the machine, remove the 

battery and store it in a fresh and dry place.

Recharge the battery approximately every three months.

Starting

•  Remove the cover 

•  Pour the mixture into the tank 

Fill the tank only after filtering the fluid, 

 in order not to damage the pump. 

Always use clean water without impurities to prepare the liquid to 

be sprayed. 

•  Set the pump operating mode (continuous - timed) by means of 

the switch on the side 

•  If the timing setting is selected, select the desired timing according 

to the product millilitres to be dispensed for each spray (check 

with the supplied measuring cup) 

•  SparaMosca is ready to be used 

•  Spray the chemical product keeping the nozzle at a suitable 

distance from the surface being treated.

NOTE: Mix the pesticide separately in a suitable container, then pour 

the solution into the tank.

Remember that, on average, approx. 200 ml of product remain 

within the pipes at the end of treatment.

Operating instructions

C

Cleaning the solenoid valve  

See the solenoid valve specification and components on page 17.

Since the solenoid valve may become clogged, remove and clean 

it thoroughly any time it is necessary. To do so: remove the fitted 

solenoid (1), unscrew the bulb (2) by 90° until it clicks, using a pair of 

pliers, then thoroughly clean the inside of the solenoid valve. Finally 

reassemble all components carefully.

Содержание SparaMosca

Страница 1: ...Quello che mancava Operation and maintenance manual version 2 2015...

Страница 2: ...dards page 9 Symbols used in the manual page 10 Important warnings page 11 Transport handling and storage page 12 Warranty page 13 Technical information Description of SparaMosca page 15 How to handle...

Страница 3: ...s taking care to observe their polarity 3 Connect the battery charger to the power supply for 12 hours 3 Close the cover pressing mainly on the left 4 Press slightly and push the cover clips upwards u...

Страница 4: ...nt 4 Using SparaMosca to spray Spintor Fly and simi lar products 1 Use the lance without extension 3 Press the button of the lance to dispense a dose of liquid 6 Use the graded cylinder to measure the...

Страница 5: ...se when reading this manual contact the nearest Casotti authorised dealer or Casotti Irroratori directly Safety standards The user must thoroughly read the technical operating instructions pertaining...

Страница 6: ...r which it is designed contact Casotti for clarifications about its use if necessary Ensure that all personnel involved in operating the equipment is properly formed SparaMosca is a sprayer of substan...

Страница 7: ...s not to be entitled to any claim for damage that may arise such as loss of profit or sales production or harvest machine downtime or any other indirect damage Returns are not allowed without the writ...

Страница 8: ...easuring cup Press the button on the lance to spray always the same pre set dosing Several thousands of sprays can be performed before needing to recharge according to the duration of the battery appr...

Страница 9: ...V diaphragm pump suitable to spray liquid or water soluble powder products Flow rate 3 8 l min Pressure 3 1 bar Timing system with adjustment potentiometer located on the pump body Timed Off Continuou...

Страница 10: ...IMPORTANT After each use make sure the switch is set to off before storing SparaMosca If the switch remains on the other two positions the battery will discharge quickly 1 SOLENOID VALVE Specification...

Страница 11: ...of the battery compartment Stand the battery in front of the open compartment with the pole tabs on the left Connect the terminals observing their polarity Red wire with red tab black wire with black...

Страница 12: ...d to be sprayed Set the pump operating mode continuous timed by means of the switch on the side If the timing setting is selected select the desired timing according to the product millilitres to be d...

Страница 13: ...motor runs smoothly but no liquid is dispensed from the tank 1 Check that the pump suction filter and the nozzle filter are clean 2 Check that the solenoid valve on the lance is operating The side swi...

Страница 14: ...plate Full original operation and maintenance manual Original of the declaration of conformity to provisions of Machinery Directive 2006 42 EC For the dealer The full Operation and maintenance manual...

Страница 15: ...EC Name and address of the person authorised to compile the Technical File Casotti Elisa Via Cerreto 8 1 43035 Felino Parma Italy The signatory of this document is Mrs Casotti Elisa who has full legal...

Страница 16: ...operation and maintenance manual version 2 2015 The information in this document is subject to changes without notice Casotti is not liable for omissions or technical or publishing errors contained i...

Страница 17: ...Casotti Irroratori Via Cerreto 10 43035 Felino Parma Phone 0521 831311 Fax 0521 336892 info casotti it Quello che mancava www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti...

Отзывы: