67
Important!
If you turn off power or if power turns off automatically after an error occurs, first confirm that
the projector’s fan is stopped. After the fan stops, unplug the power cord. An error will not be
cleared if you unplug the power cord while the fan is running.
Error Messages
Indicator Status When an Error Occurs
Fan error
Power has turned off automatically due to a fan problem. Confirm that the POWER/STANDBY
indicator is lit red (without flashing) and that the fan has stopped. After checking the POWER/
STANDBY indicator, disconnect the power cord from the projector and wait for all of the projector’s
indicators to go out. Next, reconnect the power cord and turn projector power back on. If the error
occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service
Center.
Error Indicators and Messages
Error Messages
Description and Required Action
Internal temperature is too
high. Check projector air
vents for blockage.
(POWER/STANDBY
indicator lights green.)
The projector’s internal temperature is very high. Perform the following steps.
Check for any blocking of the projector’s intake vents and exhaust vents, and
make sure that there is sufficient space around the projector. See “Setup
Precautions” (page 26).
If there is dust accumulated around the intake vents and/or exhaust vents, turn off
the projector and remove it. See “Cleaning the Projector” (page 65).
Internal temperature is too
high. The projector will turn
off.
(POWER/STANDBY
indicator light changes
from green to red.)
Power has turned off automatically due to internal overheating. Perform the following
steps.
Check for any blocking of the projector’s intake vents and exhaust vents, and
make sure that there is sufficient space around the projector. See “Setup
Precautions” (page 26).
If there is dust accumulated around the intake vents and/or exhaust vents, remove
it. See “Cleaning the Projector” (page 65).
If there is no problem with the projector’s vents, confirm that the POWER/STANDBY
indicator is lit red (without flashing), and then turn power back on again. If the error
occurs again when you turn power back on, contact your retailer or nearest
authorized CASIO Service Center.
XJ-UT Series
XJ-F Series
POWER
: Lit red
POWER
: Lit red
LIGHT
: Lit red
STATUS
: Flashes amber (Approximately
0.5-second intervals)
TEMP
: Lit red