— 12 —
Reference: It is also possible to store the adjustment data to your PC.
Execute “Save as (A)” from the File (F) menu.
Select a driver for data storage, and save the data using a name as desired.
(Note: Make sure to affix an extension “.ADJ” to the data.)
(5) Take a note of values (numbers) of following item on a piece of paper.
strobe_pwm
PASSWD (D
×
3333)
(6) Replace the Lens unit (Factory adjusted data are recorded in Lens unit).
(7) Connect an AC adaptor and a PC link cable to the camera.
(8) Set the camera in the PLAY mode, and turn on the power.
(9) Activate the ADJ program (ADJ713.EXE).
(4) Read the adjustment data that were used before the repair from the camera.
Click on the Recept button of the ADJ program.
When “receive OK” message is indicated, adjustment data will be entered into each item.