7-7.  TIME CALIBRATION SIGNAL TEST

A signal reception failure may be caused by a number of reasons.
Follow the steps shown in the 

fl

 owchart below to run the signal receiving test.

YES

YES

NO

NO

MANUAL Reception

Failure

OK

Reception OK?

Reception OK?

Check the Receiving Station

START

AUTO Reception

"Insufficient Signal" may also be the reason 
for the signal receiving fault.

Insuf

fi

 cient Signal

The time calibration signal may not be properly received under the following conditions.
•  The strength of the signal has changed due to season or time of day
•  The watch is placed in the reinforced concrete building
•  There is a broadcasting station nearby
•  Strong enough signal cannot be received due to the position of the watch

The real signal in China differs from the signal for the test with TEM cell.

*  To check the real signal reception in China, perform the inspection in the normal mode.
*  To check the signal reception for China with TEM cell, perform the inspection in the Test Mode.

7-7-1. MANUAL/AUTO 

Reception

For details of MANUAL and AUTO reception modes, refer to the Operation Guide.

MANUAL Reception

While in the Timekeeping mode, press 

 7 times to go to the Reception mode. Holding down 

 for 

two seconds starts the Reception. 
Reception OK: The time is adjusted and “GET” appears on the display.
Reception NG: The time is not adjusted and “ERR” appears on the display.

*  Press any button to end the manual reception, then the watch returns to the Reception 

mode.

*  Press any button to end the reception result display, then the watch returns to the Re-

ception mode. Or one or two minutes after displaying the result, the watch returns to 

the Reception mode automatically

* Press 

 to return to the Timekeeping mode from the Reception mode.

AUTO Reception

Turn on the AUTO Reception setting. When AUTO Reception is turned ON, the calibration signal is 
automatically received up to 6 times from midnight through early morning.
(If reception is successful once, the subsequent AUTO reception will not be conducted on the same 
day.)
Whether reception was successful or not may be con

fi

 rmed with [Last Receiving Date/Time] in the 

Reception mode.
(The date/time is updated after successful reception.)

Note:  Auto Reception is conducted only in timekeeping mode and World Time mode.

Location of the buttons

Содержание GW-9400-1

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 3410 MODULE NO REF NO S M 1228 OCT 2013 GW 9400 1 Ver 1 Feb 2016...

Страница 2: ...CLEAR 7 5 3 SETTINGS AFTER AC 8 6 DISASSEMBLY AND REASSEMBLY MODULE QW 3410 6 1 RREMOVING THE MODULE 10 6 2 REMOVING THE SENSOR 11 6 3 ASSEMBLING THE SENSOR 12 6 4 ATTACHING LED AND SPRING COIL 5140 2...

Страница 3: ...etic declination correction Bearing Memory Barometer Measurement and display range 260 to 1 100 hPa 7 65 to 32 45 inHg Display unit 1 hPa 0 05 inHg Measurement timing Periodic atmospheric pressure mea...

Страница 4: ...x6y7 x7y7 x8y7 x9y5 x9y3 x9y6 x9y4 x10y7 x12y7 x16y7 k27 k25 k28 k26 k33 k31 k34 k32 k37 k35 k38 k36 k43 k41 k44 k42 k47 k45 k48 k46 k53 k51 k54 k52 k57 k55 k58 k56 k3 k1 k4 k2 k7 k5 k8 k6 k13 k11 k1...

Страница 5: ...HF VSS VSS P10 VCH VSS P33 DET_C P22 VSS PLL_C1 VSS VSS P33 ANT1 ANT2 P00 VSS P10 VDD2 VSS VDD AC EMP PADMP1 P33 P32 VSS PADMP1 VBAT P30 P34 VSS COIL VDD2 P41 PN7 PN5 PN3 VSS PN1 VCC PN2 PN4 P40 PN6 P...

Страница 6: ...301378 6 10300759 11 10448755 18 10415262 14 10456277 9 10444615 2 10382262 8 10168959 4 10354207 15 72300511 16 72301004 7 10301378 13 10444614 9 10444615 12 10444613 5 10105010 17 10124960 3 1044461...

Страница 7: ...your parts usage and repair usage for similar models MAIN PARTS Item Code No Parts Name Specification R 1 2 10458934 MODULE WITHOUT MOVEMENT QW 3410AT 01TK 1 A 10458935 MODULE WITHOUT MOVEMENT QW 3410...

Страница 8: ...9219A 2 2 2 C 17 10124960 SPRING COIL 2763 1 Q471262 1 2 2 C 18 10415262 SPRING COIL 5140 2 RJQ552453 002V01 4 4 C For the prices and minimum order supply quantities of the above parts refer to the Pa...

Страница 9: ...lear after a battery is replaced Unless AC is performed the memory s and or counter s may not be initialized and cause malfunc tions 1 Touch the AC contact and the CIRCUIT SUPPORTER 3414 with metallic...

Страница 10: ...raph OFF Barometric Pressure Information OFF World Time WT City Code UTC Time 3 00 00 PM DST All Cities OFF Stopwatch Setting Reset 0H 00 00 00 Countdown Timer Setting Reset 0H 10 00 Start Time 0H 10...

Страница 11: ...ion OFF Display 4 directional graphic display Barometer Barometric Pressure Temperature data cleared Barometric Pressure tendency graph cleared Pressure differential graphic cleared Barometric Pressur...

Страница 12: ...ent failures The O ring for the back cover has 6H and 12H sides Be careful to place the O ring in the right direction 6 1 REMOVING THE MODULE 1 When removing the back cover do not misplace the spring...

Страница 13: ...SENSOR 1 Remove the Bezel Bezel The CAP SENSOR may come off the Bezel Do not misplace it 2 Undo two screws and the Plate Protection Screws Plate Protection 3 Remove the Plate and O ring Plate O ring...

Страница 14: ...Assembling When replacing the sensor fold the new sensor cable into shape 1 Secure the sensor in place 2 Use a pin with 1 mm diameter to shape the sensor cable Do not crease the sensor cable when shap...

Страница 15: ...ion with two screws Plate Protection hook Screws same size 5 Insert the sensor cable into the connector as far as it will go and then close the cover The Back Cover side is the pad surface Note Form t...

Страница 16: ...ING 3414 1 REFLECTOR 3414 2 Side view HOUSING 3414 1 REFLECTOR 3414 2 Glass side Cover Back side the mirror surface white part 2 Attach LED to the HOUSING 3414 1 Orientation of LED the light emitting...

Страница 17: ...4 Attach the REFRECTOR 3414 and the CUSHION 4334 1 REFRECTOR 3414 CUSHION 4334 1 5 Attach INTER CONNECTOR 3414 to the LIGHT GUIDE 3414 INTER CONNECTOR 3414 6 Attach the SPRING COIL 5140 2 for the LED...

Страница 18: ...terminals using a metal object like a staple MP terminal VSS terminal staple tape Use a stable power source and an ammeter Connect the positive electrode to the HOLDER BATTERY 2730 the negative elect...

Страница 19: ...n check the accuracy with the quartz timer Measure the accuracy value on the following conditions SENSOR GATE TIME LCD 16 seconds 2 CANCELLATION OF THE ACCURACY CHECKING MODE Press or Then the watch r...

Страница 20: ...eeping mode hold down and press and at the same time 2 Press The Home City is displayed on the LCD 3 Each time is pressed the Home City switches in the order below NYC LON PAR HKG TYO Configuration of...

Страница 21: ...2 4 Check that 8888 appears on the display indicating that light is insufficient Once 8888 appears the display remains the same even after the watch face is exposed to light Figure 3 3 To exit from th...

Страница 22: ...and AUTO reception modes refer to the Operation Guide MANUAL Reception While in the Timekeeping mode press 7 times to go to the Reception mode Holding down for two seconds starts the Reception Recepti...

Страница 23: ...ress or to return to the Timekeeping mode Or one to two hours after the last button operation the watch returns to the Timekeeping mode automatically JJY40 J40 JJY60 J60 WWVB U60 DCF77 G77 MSF L60 Sel...

Страница 24: ...CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan Ver 1 Feb 2016 Correction of page 17...

Отзывы: