QW-3410
– 10 –
6. DISASSEMBLY AND REASSEMBLY: MODULE QW-3410
Note: The pressure sensor may be replaced separately.
The temperature sensor is mounted on the
fl
exible board of the pressure sensor;
therefore, replacing the pressure sensor may repair some temperature measurement
failures.
The O ring for the back cover has 6H, and 12H sides.
Be careful to place the O ring in the right direction.
6-1. REMOVING THE MODULE
1) When removing the back cover, do not misplace the spring/coils.
SPRING/COIL 1253-2 (Au plated)
SPRING/COIL 1253-2 (Ni plated)
BACK COVER
2) Release the Connector lock.
3) Remove the Sensor cable.
Sensor cable
Connector lock
4) Please insert a precision screw driver into the gaps pointed by arrows between the module and
the case.