Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide

OL-9774-04

Chapter 2      Switch Installation

Preparing for Installation

Installation Guidelines

Before installing the switch, verify that these guidelines are met:

Clearance to front and rear panels is such that

Front-panel indicators can be easily read.

Access to ports is sufficient for unrestricted cabling.

AC power cord can reach from the AC power outlet to the connector on the switch rear panel.

The X2-10GB-CX4 transceiver module minimum bend radius and connector length is met. See 
the X2 transceiver module documentation for more information.

For switches that support the RPS 2300, confirm that you have access to the switch rear panel to 
connect the RPS 2300. If you do not have access to the rear panel, you should cable the switches 
before you rack-mount them.

For switches with the optional 1150-W power-supply module (C3K-PWR-1150WAC=), first 
rack-mount the switch before installing the power-supply module.

For power-supply modules and fan modules, tighten the module captive screws before moving the 
switch.

When connecting or disconnecting the power cord on a switch that is installed above or below a 
1150-W power supply-equipped switch, you might need to remove the module from the switch to 
access the power cord.

Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent 
lighting fixtures. Make sure that the cabling is safely away from other devices that might damage 
the cables.

For copper connections on Ethernet ports, cable lengths from the switch to connected devices can 
be up to 328 feet (100 meters).

For cable requirements for X2 module connections, see the 

“Cable and Adapter Specifications” 

section on page B-5

. Each port must match the wave-length specifications on the other end of the 

cable, and the cable must not exceed the required cable length.

Operating environment is within the ranges listed in 

Appendix A, “Technical Specifications.”

 

Airflow around the switch and through the vents is unrestricted.

Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed or 
multirack assembly, the temperature around it might be greater than normal room temperature.

Cisco Ethernet Switches are equipped with cooling mechanisms, such as fans and blowers. However, 
these fans and blowers can draw dust and other particles, causing contaminant buildup inside the 
chassis, which can result in system malfunction. You must install this equipment in an environment 
as free from dust and foreign conductive material (such as metal flakes from construction activities) 
as is possible.

These standards provide guidelines for acceptable working environments and acceptable levels of 
suspended particulate matter:

Network Equipment Building Systems (NEBS) GR-63-CORE 

National Electrical Manufacturers Association (NEMA) Type 1

International Electrotechnical Commission (IEC) IP-20

Содержание Catalyst 3560-E

Страница 1: ...e 10 Gigabit Ethernet Slots page 2 19 Installing SFP Modules page 2 22 Connecting Devices to the Ethernet Ports page 2 25 Where to Go Next page 2 28 For initial switch setup how to assign the switch I...

Страница 2: ...ement 122 Warning Ethernet cables must be shielded when used in a central office environment Statement 171 Warning Do not reach into a vacant slot or chassis while you install or remove a module or a...

Страница 3: ...ent in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statemen...

Страница 4: ...uch interconnection methods unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are mad...

Страница 5: ...radios power lines and fluorescent lighting fixtures Make sure that the cabling is safely away from other devices that might damage the cables For copper connections on Ethernet ports cable lengths fr...

Страница 6: ...uidelines Size of the switch and any optional power supply module The 1150 W power supply module is longer than the other modules Stacking switches with the same power supply modules together makes it...

Страница 7: ...g configurations for stacking the switches Figure 2 1 is an example of a recommended configuration that uses the supplied 0 5 meter StackWise cable In this example the switches are stacked in a vertic...

Страница 8: ...2 4 Stacking Nine Switches in a Side by Side Mounting Configuration Stack Bandwidth and Partitioning Examples This section provides examples of stack bandwidth and possible stack partitioning Figure 2...

Страница 9: ...ack The sequence in which the switches are first powered on might affect the switch that becomes the stack master If you want a particular switch to become the stack master power on that switch first...

Страница 10: ...lowing the same procedures Rack Mounting To install the switch in a 19 inch rack follow the instructions described in this section Warning To prevent bodily injury when mounting or servicing this unit...

Страница 11: ...ded with the switch Figure 2 9 shows the standard 19 inch brackets and optional mounting brackets and part numbers Figure 2 9 Rack Mounting Brackets 1 19 inch brackets part number RCKMNT E 1RU 2 23 in...

Страница 12: ...e attached For attachment at the front mounting position remove two Phillips truss head screws from the switch side panels Figure 2 10 For some switch models remove only one screw from the side panels...

Страница 13: ...Figure 2 11 Use three screws to attach the brackets for the mid mounting position Figure 2 11 Attaching Brackets for 19 inch Racks 1 Front mounting position 3 Mid mounting position 2 Number 8 Phillip...

Страница 14: ...chine screw black 4 Number 12 Phillips machine screws 2 Cable guide 5 Mid mounting position 3 Front mounting position 6 Rear mounting position AC OK PS OK 100 240 V 10 5 A 50 60 HZ MODE SYST RPS MASTR...

Страница 15: ...d damage to the system Statement 378 Caution You can only wall mount the Catalyst 3560E 12D switch You cannot wall mount the 24 and 48 port switches or the Catalyst 3560E 12SD switch Attaching the Bra...

Страница 16: ...side panel facing up as shown in Figure 2 14 For the best support of the switch and cables make sure that the switch is attached securely to wall studs Figure 2 14 Wall Mounting Catalyst 3560E 12D Swi...

Страница 17: ...Attaching the 19 inch Brackets for Table or Shelf Mounting When you complete the switch installation see the After Installing the Switch section on page 2 17 for more information switch configuration...

Страница 18: ...gn the connector correctly Insert the cable into the StackWise port on the back of the switch Figure 2 16 Using a ratcheting torque screwdriver tighten the retainer screws to 5 lbf in 80 ozf in Step 3...

Страница 19: ...rnet slot until you are ready to install an X2 transceiver or a converter module Either a module or an EMC plug must be installed in the slot at all times Do not remove the dust plugs from the fiber o...

Страница 20: ...ver module with fiber optic cables attached An X2 module interface might go into an error disabled state when an X2 transceiver module is inserted or removed with fiber optic cables connected to the m...

Страница 21: ...ways remove any cables and modules before installing the converter module in the slot Figure 2 19 Installing Converter Modules in 24 and 48 Port Switches and Catalyst 3560E 12SD Switches Figure 2 20 I...

Страница 22: ...e Remove the SFP modules from the converter module Step 4 Carefully pull on the X2 module sleeve or pinch the tabs on the converter module to disengage it from the slot Grasp the edges of the module a...

Страница 23: ...For switches without SFP module slots install a converter module in the 10 Gigabit Ethernet module slot as described in the Installing X2 Transceiver Modules and Converter Modules section on page 2 1...

Страница 24: ...hes Figure 2 22 Converter Module with SFP Modules Installed in Catalyst 3560E 12D Switches 1 Converter modules 3 Send TX optical bore 2 SFP modules1 1 Lower SFP modules are inverted on 24 and 48 port...

Страница 25: ...interfaces clean Step 4 If the module has a bale clasp latch pull the bale out and down to eject the module If the bale clasp latch is obstructed and you cannot use your index finger to open it use a...

Страница 26: ...n Cisco com for more information about enabling or disabling autonegotiation and auto MDIX If auto MDIX is disabled use the guidelines in Table 2 1 to select the correct cable for connecting the switc...

Страница 27: ...rt PoE when connected to the switches by a crossover cable Caution PoE faults are caused when noncompliant cabling or powered devices are connected to a PoE port Only standard compliant cabling can be...

Страница 28: ...ck configuration and monitoring You can access the device manager from anywhere in your network through a web browser For more information see the switch getting started guide and the device manager o...

Отзывы: