— 53 —
Put power supply voltage
down by degrees.
VDET1R
ON
VDET2R
OFF
Measure the voltage that
VDET1R becomes ON.
VDET1R= 3.3 V
±
2 %
Put power supply voltage
down by degrees.
VDET1R
ON
VDET2R
ON
Measure the voltage that
VDET2R becomes ON.
VDET2R= 3.0V
±
2 %
Put power supply voltage
down by degrees.
VDETS
ON
Measure the voltage that
VDETS becomes ON.
VDETS = 2.7 V
±
1 %
VDET1R
VDET2R
VDETS
Setting
Change to connect power
supply to the terminals for
rechargeable battery.
Vr = 2.6 V
Connect the items as
shown.
C h a n g e t o c o n n e c t
power supply to the ter-
minals for backup bat-
tery.
Vs = 3.0 V
Connect the items as
shown.
Step
Operation
Display (Wiring)
Note
V
-
+
A-20
Vs
Backup battery terminal
V
-
+
A-20
Charger
AC adapter
Vr
Rechargeable battery terminal