— 50 —
** Main Menu **
0 AUTO MODE
1 DISPLAY
2 TOUCH PANEL
3 MEMORY
4 SERIAL
5 POWER CONTROL
6 AUDIO
7 Others
Current Consumption and Voltage Detectors Check
Prepare the following items;
1 : Power supply
1 unit
2 : Ammeter
1 unit
3 : Voltmeter
1 unit
4 : AC adapter
1 unit
5 : Charger
1 unit
Current Consumption Check
Step
Operation
Display (Wiring)
Note
Setting
Connect the items as
shown.
Do not load the backup
battery.
1: Maximum of contrast dial.
2: Set the range of Amme-
ter to 1 A.
3: Vb = 2.6
±
0.1 V
Boot the diagnostic pro-
gram
** Main Menu **
0 AUTO MODE
1 DISPLAY
2 TOUCH PANEL
3 MEMORY
4 SERIAL
5 POWER CONTROL
6 AUDIO
7 Others
To boot the diagnostic, re-
fer to page 43.
5
Currently CPU clock is 180MHz
Push on key to exit
Current consumption at
ON.
Measure the current.
Ib = 650 mA or under.
Alkaline battery terminal
Vb
A
V
-
+
A-20
Ib
2
ON, 3
** Power Control **
1 40MHz
2 standby
3 sleep
Sleep mode
Current consumption at
SLEEP.
Measure the current.
Ib = 50 mA or under.
Main
Battery at
SLEEP
Main
Battery
ON
5
ON
Содержание Cassiopeia A-20
Страница 1: ...Handheld Personal Computer A 20 ZX 340 R DEC 1997 without price A 20...
Страница 23: ...20 7 Restoring starts 8 Click OK...
Страница 72: ...69 PCB VIEW...
Страница 76: ...73 Z370 ROM PCB ROM To Z340 1 PCB 1 3 MAIN CN7...
Страница 77: ...74 Z340 DPMI PCB MIC To Z340 LED PCB LED CN5 From Z340 1 PCB 1 3 MAIN CN4 To LCD unit CN1...
Страница 80: ...CASIO TECHNO CO LTD 8 11 10 Nishi Shinjuku Shinjuku ku Tokyo 160 Japan Telephone 03 3347 4926...