background image

ATEX 94/9/EC: 

Explosive Atmospheres and Cashco Inc. Regulators

These valves satisfy the safety conditions according to EN 13463-1 and EN 13463-5 for equipment group IIG 2 c.

Caution: Because the actual maximum temperature depends not on the equipment itself, but upon the fluid temperature, a 
single temperature class or temperature cannot be marked by the manufacturer.

Specific Precaution to Installer: Electrical grounding of valve must occur to minimize risk of effective electrical discharges.

Specific Precaution to Installer:   Atmosphere vent holes should be plugged to further minimize the risk of explosion.

Specific Precaution to Maintenance: The Valve Body/ Housing must be regularly cleaned to prevent buildup of dust deposits.

Specific Precaution to Maintenance: Conduct periodic Continuity Check between Valve Body/ Housing and Tank to minimize 
risk of electrical discharges.

Attention: When repairing or altering explosion-protected equipment, national regulations must be adhered to. For maintenance 
and repairs involving parts, use only manufacturer's original parts.

ATEX requires that all components and equipment be evaluated. Cashco pressure regulators are considered components. 
Based on the ATEX Directive, Cashco considers the location where the pressure regulators are installed to be classified 
Equipment-group II, Category 3 because flammable gases would only be present for a short period of time in the event of a leak. 
It is possible that the location could be classified Equipment-group II, Category 2 if a leak is likely to occur. Please note that the 
system owner, not Cashco, is responsible for determining the classification of a particular installation.

Product Assessment

Cashco performed a conformity assessment and risk analysis of its pressure regulator and control valve models and their 
common options, with respect to the Essential Health and Safety Requirements in Annex II of the ATEX directive. The details 
of the assessment in terms of the individual Essential Health and Safety Requirements, are listed in Table 1. Table 2 lists all of 
the models and options that were evaluated and along with their evaluation.
Models and options not listed in Table 2 should be assumed to not have been evaluated and therefore should not be selected 
for use in a potentially explosive environment until they have been evaluated.
Standard default options for each listed model were evaluated even if they were not explicitly listed as a separate option in the 
table. Not all options listed in the tables are available to all models listed in the tables. Individual TB’s must be referenced for 
actual options.
When specifying a regulator that is to be used in a potentially explosive environment one must review the evaluations in Table 1 
and 2 for the specific model and each and every option that is being specified, in order to determine the complete assessment 
for the unit.
A summary of the models and options found to have an impact on ATEX assessment due to potential ignition sources or other 
concerns from the ATEX Essential Health and Safety Requirements, are listed below.

1. 

The plastic knob used as standard on some models, (P1, P2, P3, P4, P5, P7, 3381, 4381, 1171, and 2171) is a 
potential ignition source due to static electricity. To demonstrate otherwise, the knob must be tested to determine 
if a transferred charge is below the acceptable values in IEC 60079-0 Section 26.14 (See items 25, 27, and 28 in 
Appendix A). Until the plastic knob has been shown to be acceptable, then either the metal knob option, or a preset 
outlet pressure option is required to eliminate this ignition source (See items 45 and 64 in Tables).

2. 

The pressure gauges offered as options on a few of the regulator models (DA’s, P1-7, D, 764, 521), use a plastic 
polycarbonate window that is a potential ignition source due to static electricity. To demonstrate that the gauges are 
not a potential source of ignition, the gauges would need to be tested to determine if a transferred charge is below 
the acceptable values in IEC 60079-0 Section 26.14 or the pressure gauge supplier must provide documentation 
indicating the gauge is compliant with the ATEX Directive (See items 26, 27, and 28 in Appendix A). Until compliance 
is determined, regulators should not be ordered with pressure gauges for use in potentially explosive environments.

NOTICE

Only for Product Codes wherein hazard 
category ATEX has been selected.

Содержание 123-1+6+S

Страница 1: ...t P1 pressure coming in the side body 1 connection in accordance with the directional flow arrow cast on body 1 PSIZING P1 P2 P1 PLOAD P1 PLOAD PSET PDIFFERENTIAL P1 PLOAD LOADING FLUID PLOAD DIAPHRAG...

Страница 2: ...by turning CCW Loosen lock nut 9 by turning CCW Turn the adjusting screw 17 CW to increase differential pressure or CCW to decrease Tighten lock nut 9 and replace closing cap 22 REFER TO THE COMPRESSO...

Страница 3: ...lightweight grease on the ring seals 28 29 c Lubricate adjusting screw 17 threads Carefully reinstall adjusting screw 17 up into the spring chamber 2 by rotating adjusting screw 17 CW until top of ad...

Страница 4: ...justmentscrew 17 sothatspringchamber 2 and body 1 just make contact This will keep the range spring 18 from falling over while the body 1 and spring chamber 2 are bolted back together 10 Inspect press...

Страница 5: ...ating SeeTable1 b Crack open No 1 shut off valve and allow a pressure buildup simultaneously in the body 1 and spring chamber 2 Spray the entire regulator with a liquid leak detector and visually insp...

Страница 6: ...nder D Incorrect range spring screwing out CCW of adjusting screw does not allow bringing pressure level to a stable and proper level D Replace range spring with proper lower range Contact factory E T...

Страница 7: ...vel for the product CAUTION Do not attempt to alter the original construction of any unit without assistance and approval from the factory All purposed changes will require a new name plate with appro...

Страница 8: ...r Item No Description Parts 20 Pressure Plate 21 Pusher Plate 22 Closing Cap 24 Diaphragm Covers1 27 Sealing Washer 28 Backup Ring 29 Quad Ring 30 Cap Screw Hex head 31 Pressure Plate O ring 32 Diaphr...

Страница 9: ...e evaluated and along with their evaluation Models and options not listed in Table 2 should be assumed to not have been evaluated and therefore should not be selected for use in a potentially explosiv...

Страница 10: ...y the user could possibly increase the surface temperature and must be evaluated by the user for compliance with the ATEX Directive User installation of heating systems applied to the regulator body o...

Отзывы: