background image

IOM-123-1+6 +S  DIFF

2

VI.    MAINTENANCE

A. General:

1.  Maintenance procedures hereinafter are 

based upon removal of the regulator unit from 
the pipe line where installed.

V. SHUTDOWN

SECTION V 

REFER TO THE COM PRES SOR/EXPANDER MAN U FAC TUR ER'S MANUAL FOR DETAILED SHUTDOWN OF 
THIS UNIT.

1.  On initial start-up with your system op er at ing at 

nor mal conditions, check the differential gauge to 
ensure the desired differential pressure is being 
maintained. If not, go to step 2 and make one final 
ad just ment. (This should only be nec es sary on 
first start-up.) 

NOTE:

 It is crucial that the adjusting 

screw (17) threads not be dam aged. Do not use 
pliers or locking pliers on the adjusting screw (17).

2.  To adjust differential setting, use one of these two 

methods:

  a. Loosen the closing cap (22) by turning CCW     

3-4 complete revolutions. Loosen lock nut (9) 

by turning CCW until it is tight (dou ble-nutted) 
against closing cap (22). Now the differential 
set ting may be adjusted by turning the closing 
cap (22) CW to increase differential or CCW 
to de crease. After desired setting is reached, 
loos en lock nut (9) from clos ing cap (22) and 
tighten each se cure ly to spring chamber (2).

 
  b. Remove closing cap (22) from ad just ing screw 

(17) by turning CCW. Loosen lock nut (9) by 
turning CCW. Turn the adjusting screw (17) 
CW to in crease differential pressure or CCW 
to de crease. Tight en lock nut (9) and replace 
clos ing cap (22).

 

REFER TO THE COMPRESSOR/EXPANDER MANUFACTURER'S MANUAL FOR DETAILED STARTUP OF  

 THIS 

UNIT.

IV. STARTUP

SECTION VI 

 

 

 

WARNING 

SPRING UNDER COMPRESSION. Prior to re mov ing 
spring chamber subassembly (2), relieve range spring 
(18) com pres sion by back ing out the ad just ing screw 
(17). Fail ure to do so may result  in flying parts that 
could cause per son al injury.

2.  Owner should refer to owner's procedures for 

re mov al, handling, cleaning and disposal of 
non re us able parts, i.e. gaskets, etc.

3.  Refer to Figure 5 for differential regulator 

cutaway drawing.  

WARNING 

SYSTEM UN DER PRES SURE.  Prior to performing any 
maintenance, isolate the reg u la tor from the system and 
relieve all pressure(s). Failure to do so could result in 
personal injury.

TABLE 1

MAX OPERATING PRESSURES & TEMPERATURE RATING SPECIFICATIONS

DESCRIPTION

NPT and 1500# ANSI Flg.

600# ANSI Flg.

900# ANSI Flg.

100°F  

(38°C)

400°F 

(205°C)

100°F

(38°C)

400°F

(205°C)

100°F

(38°C)

400°F

(205°C)

psig

(Barg)

psig

(Barg)

psig

(Barg)

psig

(Barg)

psig

(Barg)

psig

(Barg)

Max. Pressure for 

CS Body/Spg. Ch,

1500

(103)

1500

(103)

1480

(102)

1270

(88)

1500

(103)

1500

(103)

Max. Pressure for 

SST Body/Spg. Ch.

1500

(103)

1500

(103)

1440

(99)

995

(69)

1500

(103)

1500

(103)

Operating Temperature Range -20°F (-28°C) to +400F (+204C)

SECTION IV 

Содержание 123-1+6+S

Страница 1: ...t P1 pressure coming in the side body 1 connection in accordance with the directional flow arrow cast on body 1 PSIZING P1 P2 P1 PLOAD P1 PLOAD PSET PDIFFERENTIAL P1 PLOAD LOADING FLUID PLOAD DIAPHRAG...

Страница 2: ...by turning CCW Loosen lock nut 9 by turning CCW Turn the adjusting screw 17 CW to increase differential pressure or CCW to decrease Tighten lock nut 9 and replace closing cap 22 REFER TO THE COMPRESSO...

Страница 3: ...lightweight grease on the ring seals 28 29 c Lubricate adjusting screw 17 threads Carefully reinstall adjusting screw 17 up into the spring chamber 2 by rotating adjusting screw 17 CW until top of ad...

Страница 4: ...justmentscrew 17 sothatspringchamber 2 and body 1 just make contact This will keep the range spring 18 from falling over while the body 1 and spring chamber 2 are bolted back together 10 Inspect press...

Страница 5: ...ating SeeTable1 b Crack open No 1 shut off valve and allow a pressure buildup simultaneously in the body 1 and spring chamber 2 Spray the entire regulator with a liquid leak detector and visually insp...

Страница 6: ...nder D Incorrect range spring screwing out CCW of adjusting screw does not allow bringing pressure level to a stable and proper level D Replace range spring with proper lower range Contact factory E T...

Страница 7: ...vel for the product CAUTION Do not attempt to alter the original construction of any unit without assistance and approval from the factory All purposed changes will require a new name plate with appro...

Страница 8: ...r Item No Description Parts 20 Pressure Plate 21 Pusher Plate 22 Closing Cap 24 Diaphragm Covers1 27 Sealing Washer 28 Backup Ring 29 Quad Ring 30 Cap Screw Hex head 31 Pressure Plate O ring 32 Diaphr...

Страница 9: ...e evaluated and along with their evaluation Models and options not listed in Table 2 should be assumed to not have been evaluated and therefore should not be selected for use in a potentially explosiv...

Страница 10: ...y the user could possibly increase the surface temperature and must be evaluated by the user for compliance with the ATEX Directive User installation of heating systems applied to the regulator body o...

Отзывы: