49
E
N
G
L
IS
H
13 ALARM MANAGEMENT
If an anomaly occurs in the operation, the following procedure is activated:
1) acoustic alarm (beep);
2) one of the following system LEDs lights up:
;
3)
Press and hold the
“cancel” key to display the error code:
CODE
ERROR/WARNING
DESCRIPTION
POSSIBLE CAUSES
LED
E001
Defective control panel
Defective control panel
E002
Remote control communication signal error
Defective control panel
E004
Communication error
Connection cable between board and control panel
interrupted or disconnected.
this error
E101
Ignition failure error
Pellet quality
Faulty ignition system
Dirty burn pot
E106
Pellet probe alarm
Pellet probe disconnected or faulty
E108
Pressure or thermal safety error
Dirty fume evacuation system
Worn sealing gaskets
Problems of overheating of the pellet tank
E110
Temperature probe malfunction
Defective air probe
E111
Fume probe malfunction
Defective fume temperature probe
A002
Scheduled maintenance warning.
Periodically, the stove requires maintenance by a
specialist technician
A004
Low battery
The back-up battery (mod. CR2032) on the electronic
board is low *
A005
Hall sensor malfunction
Hall sensor on fumes fan disconnected or faulty
----
Stove cleaning
Combustion chamber, burn pot or dirty fume evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
----
Ignition failure error
No pellets: Ignition resistor faulty;
Worn gaskets; Incorrect burn pot position
for a few seconds.
If the error code is “
E108
”, manually re-arm the thermostat on the back of the stove before resetting the alarm
•
the stove has cooled down
•
the burn pot is clean and free from ash residue or pellets
•
the burn pot is correctly positioned in its seat
•
Fig. 13
004778340 - 16/07/2020