48
004778320 - 16/07/2020
12.7 MANUAL ACTIVATION OF THE LOADING SYSTEM
If it is the first use (pellet tank initially empty) or to test the loading unit operation, the load can be started
manually.
On the stove control panel:
a) Use the arrow keys to go to the set-up menu and press the key;
b) Select the password “7” with the
key and confirm with the
key;
c) Scroll with the key and select the submenu
[31]
;
d) select the password "54" with the
key and confirm with the
key;
e) When the key is pressed and held down, the loading system is activated and the increment bars are
shown on the display.
f) When the key is released, the loading operation is halted.
Attention!
•
This function is only available when the stove is switched off and cold.
• Before switching it on again, make sure that there are no pellets in the burn pot.