background image

KONFORMITÄTSERKLÄRUNG gem. 

Gesetz über Funkanlagen und Telekommunikationsendeinrichtungen (FTEG) 

und Richtlinie 1999/5/EG (R&TTE) 

Declaration of Conformity in accordance with the Radio and Telecommunications 

Terminal Equipment Act (FTEG) and Directive 1999/5/EC (R&TTE Directive

)

Hersteller/

Manufacturer

EVT/Casafan-Ventilatoren 

Inh.: Wolfgang Kissling 

Gelnhäuser Str. 35 

D 63505 Langenselbold 

Fernbedienung für Deckenventilatoren / 

Remote Control for ceiling fans 

(Tranreceiver)

Identification:

  FB FNK Advanced 

(AS-019-T  + AS-047-EMC)

Oben genanntes Produkt entspricht bei bestimmungsgemäßer Verwendung 

den grundlegenden Anforderungen des § 3 und den übrigen einschlägigen 

Bestimmungen des FTEG (Artikel 3 der R&TTE) / 

Above product complys at designated use with the basic requirements of § 3 and 

remaining regulations FTEG (Article 3 of R&TTE) 

Das oben beschriebene Produkt ist konform mit den Anforderungen der 

folgenden Dokumente 

/ The above product is conforming with the requirements of 

following documents: 

EN 300 220-2 V2.1.2:2007

EN 301 489-1 V1.8.1:2008 

EN 301 489-3 V1.4.1:2002 

EN 60215:1989+A1+A2 

EN 50371:2002 

Langenselbold 05.02.2010

                   

 

        

     

Содержание FB-FNK Advanced

Страница 1: ...t Class 1 Sub class 20 433 9 MHz ROOM TEMP AUTO AUTO 1 2 SET TEMP TIMER 1 2 3 4 F C F C H TIMER H TEMP SET DELAY OFF AUTO2 AUTO1 TIMER TIMER D Montage und Bedienungs anleitung 2 GB Mounting and operating manual 10 F Instructions de montage et de service 14 16 I Istruzioni per il montaggio e l uso 17 19 ...

Страница 2: ...d DIMMER Button Button LICHT TIMER Button ceiling fan TIMER Button ceiling fan ON OFF Button TEMP SET Button AUTO 1 Button AUTO 2 10 GB GB Errors may be caused by interference with the transmission frequency emitted by another wireless product In order to change the transmission frequency you may change the setting of all 4 DIP switches from OFF delivery condition to ON If this does solve the prob...

Страница 3: ...ng If the ceiling fan is equipped with lights these may be switched on or off or dimmed irrespective of the fan motor function 11 Technical data Type FB FNK Advanced Code Nbr 85229 Mains voltage 230 Volt 50 Hz Data transmission Radio freqency 434 MHz Power motor max 115 Watt Protection clas I No of speeds 4 Power light max 300 Watt Dimming Tungsten bulb ON OFF ESL bulb yes Weight kg ca 0 15 kg Cas...

Страница 4: ...sive environments The remote control unit must only be used to control ceiling fans Do not use for other purposes Caution Before starting with the installation please make sure that the pull switch on the fan is set to the highest speed Any damage caused to the circuitry of the remote control s receiver due to faulty installation is not covered by the remote control s warranty Only operate the uni...

Страница 5: ...age is switched on again the ceiling fan is available to operation with the remote control Canopy Canopy Downrod Downrod Receiver diagram 2 diagram 1 13 Please install the receiver unit of the remote as shown in diagram 3 Once the device is electrically in stalled you may stick the receiver unit to the ceiling with the double sided sticky points If this fails e g when the ceiling decoration is too...

Страница 6: ...or operation Coding of the FB FNK Advanced The remote control receiver diagram 4 and transmitter unit diagram 5 must have the same code Put the switch in the desired position you selected factory default is up for all swit ches Please use a small screwdriver or a ballpoint to do this diagram 4 diagram 5 14 Battery Typ 9V 6F22 Code DIP 1 4 Battery Code DIP 1 4 GB Light DIP 5 DIP 5 If DIP 5 set to O...

Страница 7: ...SET TEMP TIMER 1 2 3 4 F C F C H TIMER H TEMP SET DELAY OFF AUTO2 AUTO1 TIMER TIMER FAN TIMER ROOM TEMP AUTO AUTO 1 2 SET TEMP TIMER 1 2 3 4 F C F C H TIMER H TEMP SET DELAY OFF AUTO2 AUTO1 TIMER TIMER FAN TIMER SETTING Press the FAN TIMER button the light timer sym bol blinks on the display With the buttons you are able to adjust the time at which the fan switches itself off ranging from 30 minut...

Страница 8: ...ed 2 second highest speed when room temperature drops 4 C below the set max room temperature Or fan speed switches to speed 1 lowest speed when room temperature drops 6 C below the set max room temperature If the room temperature increases during one of the phases then the motor will also run at a corre spondingly higher speed Or the fan is switched off when room tempera ture drops 7 C below the s...

Страница 9: ... the highest speed max pre set fan speed when room temperature is higher than or equal to the set max room temperature Or fan speed switches to second highest speed depending on the max preset fan speed when room temperature drops 2 C below the set max room temperature However this is only the case when speed 2 is preset as the max fan speed Or fan speed switches to third highest speed depending o...

Страница 10: ...eiten und Entsorgen sowohl direkt als auch durch Teilnahme an einem Kollektivsystem in Deutschland Stiftung EAR nach GB IMPORTANT This product conforms to EU Directive 2002 96 EC This appliance bears the symbol of the barred waste bin This indicates that at the end of its useful life it must not be disposed of as domestic waste but must be taken to a collection centre for waste electrical and elec...

Страница 11: ...er receiver Identification FB FNK Advanced AS 019 T AS 047 EMC Oben genanntes Produkt entspricht bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des 3 und den übrigen einschlägigen Bestimmungen des FTEG Artikel 3 der R TTE Above product complys at designated use with the basic requirements of 3 and remaining regulations FTEG Article 3 of R TTE Das oben beschriebene Produkt ist ko...

Страница 12: ...rungen die der Verbesserung dienen behalten wir uns ohne besondere Ankündigung vor CasaFan reserves the right to make improving changes on products on sale CasaFan 2011 CasaFan Gelnhäuser Str 35 D 63505 Langenselbold ...

Отзывы: