FILE NAME ( SM_VersaTouch.pmb ras 04-01-03303303)
Casablanca Fan Co. - Factory Service Department - Technical Library
Chapter (5)
V- 5.27
To remove choke coil you need to remove the two outer
screws and disconnect the light circuit connectors.
Check to make sure choke rubber mounting pads are
good if torn or cracked these should be replaced.
NOTE : Reconnect the choke coil the same way
as it was blue wire connector from receiver to blue
connector on choke coil and black wire from choke
coil to wire connector from motor that may be blue
or black.
R
ECEIVER REPLACEMENT PROCEDURE
( CU - 188 X 20 Spinner Motor continued )
With new parts installed and dip switches set fan motor
and electronics can now be tested for proper operation
if light flickering is experianced the choke coil will have
to be replaced with a new choke coil.
Choke coil Part # 7854040 and four rubber mounting
pads Part # 7854050 supplied with two 8-32 X 3/8 mount-
ing screws.
Electronics PC Board (Transmitter)
-
CONTINUED