PREPARATION INSTRUCTIONS

Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them
against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.

CEILING HARDWARE

CROSSBAR

MOUNTING

BRACKET

WIRE NUT (4)

FAN PREPARATION

GETTING STARTED

Installing a New Ceiling Fixture Outlet Box

If you do not have an existing fixture located where you wish
to place your Casablanca fan, an approved ceiling fixture
outlet box must be installed and wired.

Using Existing Ceiling Fixture Outlet Box

After turning the power OFF at its source (either circuit breaker
or fuse box), lower the old fixture and disconnect the wiring.
Check the ceiling fixture outlet box to be sure that it is
marked ‘

Approved for ceiling fan mounting

’. If it is not, a new

box must be installed.

Warning: To reduce the risk of fire, electrical shock,
or personal injury, mount to outlet box marked
acceptable for ceiling fan support using the mount-
ing hardware provided with the outlet box.

ADDITIONAL HARDWARE

2

1

/

4

″ 

x 8-32 ROUNDED

HEAD SCREW (2)

FLAT WASHER (2)

1

 x 8-32 ROUNDED

HEAD SCREW (2)

PERMA•LOCK™ HARDWARE

Casablanca

C

APISTRANO

DOWNROD & BALL

ASSEMBLY

ALLEN SET SCREW

1

4

-20 x 

1

4

"

(PRE-INSTALLED)

3mm

ALLEN WRENCH

Prepare for fan installation as follows:
Step A.

  Route the wires from the motor through the

Perma•Lock™ downrod and ball assembly.

Step B.

 Using the provided allen wrench, loosen the set screw

several turns to allow installation of the downrod.  Thread
the downrod into the motor coupling until it stops turning,
this will take at least four and a half full turns.

Step C.

 Securely tighten the set screw with the provided allen

wrench to ensure safe operation of your fan.

Tip:

 The downrod has a tapered thread

that is designed to lock completely when
correctly installed.

CAUTION: Failure to fully lock in the down-
rod before securely tightening the allen set
screw may cause the fan to separate from
the downrod during normal operation!

IMPORTANT SAFETY INFORMATION!

BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, INSTALL THE

THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY

MOTOR

COUPLING

TAPERED

THREAD

MOTOR

WIRES

GROUND

WIRE

ALLEN

SET SCREW

DOWNROD

& BALL

ASSEMBLY

Содержание C CasablancaCAPISTRANO

Страница 1: ...T INTRODUCTION 1 MOUNTING RECOMMENDATIONS 2 PREPARATION INSTRUCTIONS 3 FAN INSTALLATION 4 CONTROL FEATURES 3 SPEED OPERATION 10 TROUBLESHOOTING 12 VERSA TOUCH 2 13 TROUBLESHOOTING 15 BEFORE YOU START...

Страница 2: ...vide sufficient clearance for the blades In bedrooms fans work best when mounted above the foot of the bed Over pool tables be sure to provide plenty of clearance to avoid damage from pool cues In low...

Страница 3: ...ided with the outlet box ADDITIONAL HARDWARE 21 4 x 8 32 ROUNDED HEAD SCREW 2 FLAT WASHER 2 1 x 8 32 ROUNDED HEAD SCREW 2 PERMA LOCK HARDWARE Casablanca CAPISTRANO DOWNROD BALL ASSEMBLY ALLEN SET SCRE...

Страница 4: ...EW 4 OUTLET BOX MOUNTING HARDWARE Note On sloped ceilings align the canopy opening towards the top or room peak Proceed with installation as follows Step 1 Route the wires from the ceiling outlet box...

Страница 5: ...e the canopy opening CAPPED BLUE D1 OPTION WIRE ON 3 SPEED ONLY FOR INDEPENDENT W 80 LIGHT CONTROL PIN SLOT BALL Casablanca CAPISTRANO CANOPY HATCH INSTALLATION Step 5 Tuck the wires into the canopy w...

Страница 6: ...the blade holder mounting holes in the fan motor the dummy switch housing must be removed Take out the two 5 32 X 9 32 screws secur ing the dummy switch housing and remove Put the two 2 screws aside...

Страница 7: ...lade holder securing it with the four blade screws provided Using the screwdriver tighten securely by hand only BLADE SCREW 4 PER BLADE BLADE BLADE HOLDER BLADE INSTALLATION Step 11 On the flywheel re...

Страница 8: ...REMOVED IN STEP 8 5 32 X 9 32 2 SWITCH HOUSING CONNECTOR SOCKET MOTOR CONNECTOR PLUG 3 SPEED SWITCH HOUSING AND CAP ASSEMBLY CAP SCREW 8 32 X 3 8 2 Note Save these two screws they will be used in Ste...

Страница 9: ...ng Tighten securely by hand only INSTALLING THE SWITCH HOUSING CAP Step 16 Line up the two inner clear ance holes in the cap with the two threaded holes in the switch mounting plate standoffs Step 17...

Страница 10: ...ght option wiring To install a W 40 wall control in place of an existing wall switch follow the instructions on the W 40 package Note No rewiring is required if the fan is replacing an existing light...

Страница 11: ...ur 4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by th...

Страница 12: ...k all wire connections making sure the power is turned off during this inspection Check that reverse switch is not set in center of throw FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into...

Страница 13: ...ONTROL BRACKET ROCKER TYPE LIGHT SWITCH SWITCH COVER PLATE Wall Installation Step A Locate a 2x4 wall stud in a convenient location Step B Orient the control bracket as shown over the 2x4 stud Step C...

Страница 14: ...i Med and Low buttons in that order within 20 seconds Step 4 The fan should now function properly VERSA TOUCH 2 CHANGING FREQUENCY SETTING You will only have to change the dip switch settings in the r...

Страница 15: ...de screws and or the light bulb s OPERATION Tighten canopy screws and mounting plate assembly Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fal...

Страница 16: ...r 188mm x 20mm Direct Drive Blade Span With 45 or 53 Blade Pitch 16 No of Blades 5 Technology 3 Speed Versa Touch2 W 72 Airflow 6 691 cfm Electricity Use 89 watts Airflow Efficiency 75 cfm watt Perfor...

Отзывы: