background image

10

Send Signal 

Led

Fan Control

To  start  the  fan.  Press  the  selected  speed  button  to  run  the  fan  at  the  desired 

speed.

LOW=Low speed    MED=Medium speed     HIGH=High speed

To turn off the fan, press the FAN OFF  button.

airflow direction

To reverse the airflow, press the reVerse button. reVerse operates at any speed 

whether the fan is on or off. The fan returns to its set speed after reversing.
Light Control

Turn the light on or off independently from the fan by pressing the LIGHT button. 

If you press the button for more than 0.7 seconds, it becomes a dimmer. The light 

varies from “bright" to “dim” over approximately 8 seconds. If you continue to hold 

the LIGHT button, this sequence will reverse when the light reaches its brightest or 

dimmest level. Release the button when the desired level is reached.
Memory Feature

The last light fuction and fan speed will resume when power is turned back on.
Auto Resume

Quick (pressing less than 0.7 seconds) on/off operation of the LIGHT button maintains 

the desired brightness level set previously.  

If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed cor-

rectly in the control.
Step 2. Turn the power off to the fan (from the circuit breaker) 

for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and 

push the HIGH, MED, and LOW buttons–in that order–within 

20 seconds.
Step 4. The fan should now function properly.

CHAngIng TRAnSmITTER FREqUEnCy SETTIng

You will only have to change the dip switch settings in the 

remote if you are using more than one fan in the same area 

and want to control them separately.
Step 1. At the circuit breaker or fuse box, turn the power off 

for the fan you want to change.

step 2. open the battery door of the Versa•Touch control and 

remove the batteries.
Step 3. Change the dip switch settings, assuring that they are 

different from the previously installed Versa•Touch fan.

Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back 

on for the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the HIGH, 

MED, and LOW buttons (in that order).

CIrCuIt 

Breaker

or FuSe BoX

PreSS In thIS order to Set 

new FrequenCy:

1. hIgh     2. Med      3. Low

dIP SwItCh

Set to 

“01001”

dIP SwItCh

Set to 

“10000”

Versa•Touch 2

ControL

(BaCk)

Low

Med

hIgh

LIght

Fan

oFF

reverSe

1

2

3

Note: You may want to label your controls to assure 

you do not mix them up.

REmOTE OpERATIOn

warning!
Do not turn the power off at the circuit breaker, then 

back on, for the previously installed Versa•Touch2 

fan(s),  as  you  may  inadvertently  change  the 

frequency settings for it as well.

Note: All fans leave the factory set to “00000.”

A

urorA

 II

Содержание AURORA II

Страница 1: ...cian should be consulted if you are unsure This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new...

Страница 2: ...be a minimum of 7 above the floor Do not locate the fan in a doorway or above a swinging door In any installation the tips of the blades must be at least 18 from the wall in order to provide suf fici...

Страница 3: ...W 21 4 2 FLAT WASHER 2 SCREW 1 2 Aurora II Prepare for fan installation as follows Step A Remove the paper shield from top of motor Step A1 Route the wires from the motor through the Canopy Cover Ring...

Страница 4: ...duce the risk of personal injury use only the mounting hardware provided with the approved outlet box to install the crossbar mounting bracket Aurora II Lag Screw Installation NOTE This step is requir...

Страница 5: ...On sloped ceilings align the canopy opening towards the top or room peak CANOPY ELECTRICAL CONNECTIONS Step 5 Attach the fan wires to the ceiling fixture outlet box wiring by twisting the bare ends o...

Страница 6: ...BLADE switch housing mount shoulder Screw 8 32 X 3 8 3 Aurora II Step 6 Tuck the wires into the canopy with the wire nuts pointed upwards so that the WHITE and BLACK wires are on opposite sides of th...

Страница 7: ...y BLADE HOLDER SCREW 2 PER BLADE switch housing mount SHOULDER Screw 8 32 X 3 8 3 removed in step 10 Note Versa Touch models will have only a wire nut capping the black and white wires coming out of t...

Страница 8: ...im of the switch housing with the three clearance holes in the switch housing mount Carefully slide the switch housing into the mount so that the threaded holes are directly behind the clearance holes...

Страница 9: ...Mounting Holes Control Bracket Rocker Light Switch Switch Cover Plate Wall Installation Step A Locate a 2x4 wall stud in a convenient location Step B Orient the control bracket as shown over the 2x4 s...

Страница 10: ...the power back on at the circuit breaker and push the High Med and Low buttons in that order within 20 seconds Step 4 The fan should now function properly ChangingTransmitter Frequency Setting You wi...

Страница 11: ...he light fixture retaining screws glass shade screws and or lightbulb s Tighten the canopy screws and mounting plate assembly Make sure the wire nuts inside the canopy and switch housing are not touch...

Страница 12: ...umber 42UxxLM Dimensions A 12 B 12 75 C 3 D 12 5 E 6 7 Weight 26 4 lbs Motor 188mm x 20mm Direct Drive Blade Span 53 Blade Iron Pitch 14 No of Blades 5 Technology Versa Touch2 W 72 Airflow 6 813 cfm E...

Отзывы: