background image

 

14 

7. Setup Mode 

Make sure that power is OFF. While pressing the 

key, press the 

  key. The display shows “U 

SEt”. You can select each menu by pressing the 

key and change the setting by pressing the 

 key. 

If you press 

 

key, you can save current setting and go next mode. 

 
 

 

Set up Mode Table 

 

MENU 

DISPLAY 

DESCRIPTIONS 

Do not use Auto Power Off function. 

Power turns to be off automatically when the scale is not in operation 
over for 10 minutes. 

Power turns to be off automatically when the scale is not in operation 
over for 30 minutes. 

Auto 

Power Off 

Power turns to be off automatically when the scale is not in operation 
over for 60 minutes. 

Sleep mode is deactivated. 

Sleep mode is activated after 20 seconds. 

Sleep mode is activated after 40 seconds. 

Sleep Mode 

Sleep mode is activated after 1 minute. 

 

 

 

* "e" value may be various on capacity of product model. 
Please refer to "SPECIFICATION" on page 16. For example, a product model which capacity is 
3.000kg has 1g as "e" value 

Содержание WEIGHING SOLUTION SWII PLUS Series

Страница 1: ...2...

Страница 2: ...NCTIONS 6 OPERATIONS 8 1 Simple Weighing Mode 8 2 Weighing with Tare 8 3 Changing Unit of Weight 9 4 Hold Function 9 5 Comparator Function 10 6 Counting Function 11 7 Setup Mode 14 BATTERY MAINTENACE...

Страница 3: ...4...

Страница 4: ...5...

Страница 5: ...with outstanding performance Your special departments can enjoy these high quality reliable CAS products We believe that your needs will be satisfied and you will have proper reliability This manual w...

Страница 6: ...long time Unit is converted Used to input or cancel the weight of tare Used to make the weight of commodity stable This weight is average value Used to change the unit of weight and shown as followin...

Страница 7: ...AGE section for more information on page15 When the weight becomes stable the display shows the stable sign on You may need to make it 0 000 by pressing key unless the display indicate 0 000 under the...

Страница 8: ...w the weight of the container with symbol Press the key then display will show the 0 000 3 Changing Unit of Weight Press the key a few seconds You may select kg or g as the unit of weight 4 Hold Funct...

Страница 9: ...y Press key to set up HIGH limit The display shows 2 000 and you can change these numbers by pressing key If you want to move to next digit you can go by pressing key If you set up HIGH limit you can...

Страница 10: ...oaded is above 2 990kg HIGH limit the scale continues to beep rapidly 6 Counting Function Counting without Tare Initial display as above Press key twice to go to sample unit selection mode Press the k...

Страница 11: ...the scale and press key to set weight of tare You can select 10 20 30 40 50 60 70 80 90 100 200 300 400 or 500 as a sample unit by pressing key If the number of selected sample unit is 20 please put...

Страница 12: ...nction When you try to set the number of sample unit at the stage the display may show LACK message shortly The result of counting may be incorrect in the following cases a unit weight 1 2 e b weight...

Страница 13: ...ale is not in operation over for 10 minutes Power turns to be off automatically when the scale is not in operation over for 30 minutes Auto Power Off Power turns to be off automatically when the scale...

Страница 14: ...f the battery is full Error Message on Display Description Solution The Err 0 occurs when scale is not stable Remove unstable facts The Err 1 occurs when a current zero point has shifted from the last...

Страница 15: ...HI OK LO PCS Keys ZERO UNIT TARE HOLD MODE POWER Functions Weighing Hold Unit Conversion Counting Counting Sample Range 10 100 200 300 400 500 Weight Comparison Function hi ok low Auto Power Off Funct...

Страница 16: ...17...

Страница 17: ...18...

Страница 18: ...19...

Страница 19: ...20...

Отзывы: