7
4
. POWER PACK
& CELL
ELECTRODE
INSTALLATION
Important Notes
•
The pump ra ng must not exceed 8amps
.
• Saltwater may damage Junc on Box and electrical components in the Power Pack.
•
DO NOT
use a drill to ghten Junc on Box screws – this may strip them – use a hand
held screw driver.
WARNING:
• We
DO NOT
recommend the use of valves on the inlet or outlet of the cell housing. If you
do use a valve then it is important to ensure that the valve cannot deadhead (lock closed)
while the pump is running. It is the installers responsibility to ensure some form of flow
control is installed in this instance and it disables the pump.
•
ALWAYS
ensure that pipe work and equipment do not allow gases generated from the cell
to collect and build up in any part of the installa on.
• It is
RECOMMENDED
that the Cell Housing be installed horizontally to create a natural gas
trap that acts as a safety device. Installa on in any other way may cause explosion, injury
or death if the installer does not allow for gas removal.
• The Cell Housing must be installed in the
RETURN
pipework to the pool. It must always be
installed a er the filter, gas heater, solar hea ng or heat pump.
•
DO NOT
apply priming fluid to the Cell Housing, it is not needed and may react with the
plas c.
PUMP
RETURN
TO POOL
FROM
SKIMMER BOX
4.3 Installa on Diagram
WARNING:
DO NOT
plug in if carton has been wet.
CELL
FILTER
Water turbulance has less impact
on plates with entry this end but
Cell can be plumbed either way.
POWER PACK
Ensure
good
ven la on
POWER
OUTLET
Make sure
that screws
are ght on wires
and colours match.
Red: Closest to front
White: Centre
Black: Closest to rear
Should you require further informa
tion
visit
www.
crystalas
.com