CAS Talline Скачать руководство пользователя страница 20

11. WARRANTY

12. TECHNICAL SUPPORT

20

For all warranty enquiries please contact your local distributor or contact 

Crystal Aquatic Systems

 

directly and we will either direct you to your nearest authorised repairer or assist you with your 

enquiry. 

Crystal Aquatic Systems 

Contact

 

Details

C

laiming warranty on your Talline

 Chlorinator

Disclaimer

Informa on in this guide is intended to provide general informa on on a par cular subject(s) in 
good faith and is not an exhaus ve treatment of such subject(s). Its use is beyond the control of the 
author, contributor, publishers and distributors and should not be relied upon without consul ng 
qualified, professional and comprehensive advice.

This guide includes subject(s) that should only be performed by or under the direc on and advice 
of qualified and licenced professionals and under no circumstances should the guide be used as a 
subs tute for such professionals. 

No representa ons or warran es are made that the content, advice and recommenda ons in this 
guide are current, free from errors or omissions, or appropriate for the user’s circumstances or 
abili es. No liability or responsibility is accepted for any loss suffered as a result of any user’s 
reliance on such content.  

Repairs  should  only  be  carried  out  by  qualified  persons  or 

Talline

  appointed  agents.  

Crystal Aquatic Systems

 reserve the right to refuse warranty if any damage caused to the 

chlorinator or auxiliary pool equipment that is not a result of a manufacturer’s defect. 

When making a warranty claim, please note the following informa on MUST be provided or claim 
may not be approved. 

Model Number

Power Pack

 

Serial Number

Cell Serial Number

Proof of Purchase showing the Purchase 

Date and Purchased From

Installa on Date

Installer

Your Full Name

Your Phone number

Your 

A

ddress Details

Details of the Issue

We keep extensive production and after sales records so this information will expedite the processing of your 

claim. Crystal Aquatic Systems reserve the right to modify any model without notice.

– 0

7 5593 5494

F

 – 0

7 5593 6072

– service@

crystalas

.com

 

W

 – www.

crystalas

.com

Should you require further informa

tion

 

visit

 www.

crystalas

.com

 

Содержание Talline

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS MODEL TL RANGE s a l t w a t e r c h l o r I n a t o r Talline...

Страница 2: ...ctrode Installa on 6 4 3 Installa on Diagram 7 5 Power Pack Opera on 8 5 1 Timer Switch 8 5 2 Cell Switch 8 5 3 Circuit Breaker 8 5 4 AC Socket Pump Outlet 8 5 5 Junc on Box 8 5 6 and Bu ons 8 5 7 Out...

Страница 3: ...aller must ensure that the Electroly c Cell is never energised when the pool pump is OFF or water is not owing throughtheunit 1 1 Important Warnings This manual contains important informa on about the...

Страница 4: ...s a vital part of a complete maintenance program and will ensure trouble free performance as well as a healthy and sparkling clean pool The Talline range is a reverse polarity model known as TL which...

Страница 5: ...We recommend 3 5kg per 1000 litres 1 cubM of pool water and a 50 000 litre 50 cubM new pool needs approximately 175kg of salt The unit can operate on mineral magnesium chloride salts and you should al...

Страница 6: ...the controls on the Power Pack 4 2 Cell Electrode Installa on Connect the Cell Housing horizontally in the return line to the pool use reducing bushes supplied if 40mm PVC pipe using high pressure PV...

Страница 7: ...he installa on It is RECOMMENDED that the Cell Housing be installed horizontally to create a natural gas trap that acts as a safety device Installa on in any other way may cause explosion injury or de...

Страница 8: ...erated electrical switch designed to protect an electrical circuit from damage caused by overcurrent overload or short circuit It can be reset by pressing the bu on in a er it has tripped It may be da...

Страница 9: ...ll 8 Output LED s indicate salt levels are correct and if they do not reach 8 then salt levels need to be checked or contact your local Crystal Aquatic Systems agent for assistance 5 11 Start Up Proce...

Страница 10: ...ol givingit metodoitswork Winter Se ngs Inwinteryoushouldloweryourrunning mebyupto50 ofyoursummerse ngdependingon your free chlorine levels You should ideally run 2 3 hours in the morning and 2 3 hour...

Страница 11: ...s charging at rst but simply leave it alone and it will charge itself as required This me is set at 8 00am and the dial pointer shows the 8 00 posi on as does the clock face hands The Timer comes on w...

Страница 12: ...nt salt will damage your Cell The unit will operate with good stability on higher salt levels but it is s ll advisable to run at the correct leveltopreventdamage Saltlevelsabove5000ppmmayoverloadtheun...

Страница 13: ...does not become too corrosive or end up scaling the surface of your pool These are symptoms of swimming pool water that is unbalanced 7 6 Stabiliser Measurement Interval Every 4 6 weeks IdealStabilise...

Страница 14: ...ds are in sound condi on at least once a year 8 1 Inspec ng and Cleaning the Power Pack Li le or no maintenance is normally required with the Talline Chlorinator Power Pack Ensure the Power Pack 3 pin...

Страница 15: ...mmerse the electrode in cell cleaning solu on A solu on can be made by mixing 1 part hydrochloric acid to 10 parts of water If excessive build up is present a stronger solu on may be used to remove th...

Страница 16: ...e Bu on 2 If green LED s do not increase 3 Check Cell lead connec on at the Junc on Box repair if damaged or return for service Ensure su cient water ow through Chlorinator Cell Check that the pump is...

Страница 17: ...MANUAL for normal running Poten al Cause Remedy Pump not plugged into chlorinator 9 8 Cell not cleaning excessive calcium build up on Cell or Power Pack not changing direc on 1 See Calcium Hardness t...

Страница 18: ...55 MODEL VOLTS Vac Input 210 265 210 265 210 265 VOLTS Vdc Output 188 5 318 0 227 5 Frequency Hz Weight kg Dimensions cm AMPS Adc Output 15 0 25 0 17 5 8 89 8 14 8 85 41L x 35W x 19H 41L x 35W x 19H 4...

Страница 19: ...24 months Adverse opera ng condi ons beyond the control of the manufacturer such as improper voltage or water pressure excessive ambient temperature or any condi on that adversely a ects the performan...

Страница 20: ...da ons in this guide are current free from errors or omissions or appropriate for the user s circumstances or abili es No liability or responsibility is accepted for any loss su ered as a result of an...

Отзывы: