background image

 

23

4. How to Enter Time 

 

 
 
 
 
 
 
 
 

 

 Press the MODE key until the 

display shows “ti ON”. It 
means that time is printed out. 

 

If you do not want to print out time, press the HOLD(

) key. 

 
 
 
 
 
 
 
 
 
 

 

 Press the SAMPLE(

) key 

to set up time, “00,00,00” 
is shown on the display. 

 

Press the HOLD(

) or 

PRINT(

) key to have 

number up or down. To enter 
next digit, press the 
SAMPLE(

) key. 

 

Press the SET key to save. 

“tisave” is shown on the 
display. 

 

 If you do not want to save time, press the ZERO key. 

 

Содержание DB-II series

Страница 1: ...2 ...

Страница 2: ...ONTENTS PRECAUTIONS 4 PREFACE 6 NAMESAND FUNCTIONS 6 OPERATIONS 8 SETUPMODE 20 ERROR MESSAGES 25 SERIALINTERFACE 25 SPECIFICATIONS 26 HOWTO INSTALLDB II Series 27 ASSEMBLINGTHE DISPLAY OFDB II WALLTYPE 28 ...

Страница 3: ...4 PRECAUTIONS ...

Страница 4: ...5 ...

Страница 5: ...reliability under rigid quality control and with outstanding performance Your specialty departments can enjoy with CAS products We hope that CAS product meets your needs The user manual is designed to guide you to understand product operation and proper care of product NAMESAND FUNCTIONS OVERALLVIEW ...

Страница 6: ...key in Setup Mode Used to enter a tare weight and used to cancel a tare weight Used to convert the mode as below WEIGHING pcs WEIGHTLIMITON OFF COUNTLIMITON OFF UNITCONVERSION WEIGHING UsedasanENTERkey Usedtocalculateaunitweightofasample Usedtoenternextdigit Usedtodisplayaverageweight Usedtohavenumberup ...

Страница 7: ...T Turnonthepower Thedisplayshows0 00 MakesurethatSTABLEand ZEROlampsareon Whenthedisplayisnotzero thoughthereisnothingon theplatter presstheZERO key Placeanitemontheplatter WhentheSTABLElampis on readtheweight 2 Weighing with Tare Tareistheweightofcontainerbeingusedforacommodity TheTAREkeysubtractstheweightofthecontainer Placethecontaineronthe platter PresstheTAREkey NET lampison Placeaniteminthe ...

Страница 8: ...samplesize OR PresstheMODEkeyuntilthedisplayshows PCSSET Make surethatPCSlampison Ifyouhavesetsamplesizebefore thedisplayshows 0 PresstheSAMPLEkey thenthedisplayshows 10 Ifyouwanttoincreasesamplesize presstheSAMPLEkey Thedisplayshows10 20 30 40 50 100 150and200every timepressingtheSAMPLEkey Ifyousetsamplesizeto10 place10samplesontheplatter ...

Страница 9: ...fLow 0 1g Low 0 1g Low 0 1g Low 1g Low 1g Low 1g Low Table1 Placepartsontheplatter thenthedisplayshowsthenumber ofparts Youcanalsousetarefunctionincountingmode 4 Percent Weighing Mode Theweightisdisplayedasapercentageofthereference OR PresstheMODEkeyuntilthedisplayshows PErSEt Ifyou havesetreferencesamplebefore thedisplayshows 0 0 Ifyouwanttousecontainer placeitandpresstheTAREkey Placereferencesam...

Страница 10: ...ess Hold key to save and exit to normal mode Place an item on the platter Then weight display will show Hold The Hold blinks for two times and then the average weight blinks continuously After remove the item of the platter place another item on the platter Then display will show average weight again If you don t want use auto hold function remove the item and press hold key Display shows AH_on Pr...

Страница 11: ...scalestoresdata Thisfunctionisonlyavailableinweighingmode Placeanitemontheplatter Toaddthisweight presstheSAMPLEkey Makesurethat SUMlampison ThedisplayshowscumulativeweightsumandaggregatetimeseverytimepressingtheSETkey TheSUMkeyisflashed Tocancellastaddedweight presstheSETkeytodisplaycumulativeweightsumoraggregate timesandthenpresstheSAMPLEkey Thedisplayshows SSUB ...

Страница 12: ...ghtsumoraggregatetimes PresstheSETkeytodisplay cumulativeweightsumoraggregatetimesandthenpresstheZERO ESCkey Toprintoutcumulativeweightsum presstheSETkeytodisplaycumulativeweightsumor aggregatetimesandthenpressthePRINTkey DEPonly ...

Страница 13: ...hows L000 00 PresstheHOLD or PRINT keytohave numberupordown Toenter nextdigit presstheSAMPLE key PresstheSETkeytosetup highvalue thedisplay shows H000 00 PresstheHOLD or PRINT keytohave numberupordown Toenter nextdigit pressthe SAMPLE key IfyousetupLOW HIGHlimitwrong WLERR willbeshownonthedisplay Thenyouhavetosetit upagain Forexample LOW 100 00kgHIGH 90 00kg HighlimitislowerthanLowlimit PresstheMO...

Страница 14: ...age17 7 2 Countingcomparison function PresstheMODEkeyuntil thedisplayshows CLOFF Itmeansthecounting comparisonfunctionis deactivated PresstheHOLD keyto activatethisfunction the displayshows CLON PresstheSETkey the displayshows L00000 PresstheHOLD or PRINT keytohave numberupordown Toenter nextdigit pressthe SAMPLE key PresstheSETkey the displayshows H00000 PresstheHOLD or PRINT keytohave numberupor...

Страница 15: ...W 00100 HIGH 00100 PresstheMODEkeytogotoweighingmode SupposethattheHighlimitof200andtheLowlimitof80aresetup Inthiscondition OKlampis lightedoniftheweightis120 HIlampislightedoniftheweightis220andiftheweightis60 LOlampislightedon ItbeepsasfixedonUserSetupMode RefertoSetupModeTableonpage17 PresstheSETkey the displayshows CLON ...

Страница 16: ...SETVALUE Limit H 2000pcs Limit L 1000pcs When theweightcomparisonfunction isset When thecountingcomparisonfunction isset CumulativeWeightSumFunction DEPonly WEIGHT WELCOMETOCAS DB 2 DATE 07 30 2007 TIME 17 35 58 Weight 40 180kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 200kg Weight 40 20...

Страница 17: ...ormat Barcode setasOFFandweightcomparisonfunctionas OFFinSETUPMODE 2 Weight Tare Barcode Inordertousetheabovelabelformat Barcode setasONandweightcomparisonfunctionas OFFinSETUPMODE 3 countingfunction QuantityComparisonFunctionsshouldsetasON 4 Weightcomparisonfunction WeightcomparisonfunctionsshouldsetasON WhenusingDLPprinter itcouldnotprintinthepercentagemode ...

Страница 18: ...gmassageisshownwhenthebatteryvoltageisverylow Atthistime chargethebattery achargingbatteryonly Thedisplaywillshowaredlampandthebatterywillbeginafastcharge automatically Useonlytheacadapterwhichcomeswiththescale OtherACadaptermay causedamege 10 Unit conversion kg lb oz PresstheMODEkeyuntil thedisplayshows Ukg or yourlastunit Use HOLDkey or PRINTkey youcansetwhich unityouwanttouse kg lb oz Press SET...

Страница 19: ...rintwhenthescaleisstable DLP DEP Printmethod Pr Str Ptintcontinuallywhenthescaleisstable DEP Linefeed DEPonly LF1 LF9 Linefeed Barcode DLP only BCon off Printoutbarcodeon off br 48 4 800bps br96 9 600bps br192 19 200bps Baud Rate br 384 38 400 bps bLon Use back light bL10 Back light is on 10 seconds bL30 Back light is on 30 seconds Backlight bL oFF Do not use back light Brightness 1 7 Youcansetbac...

Страница 20: ...You will hear buzzer Count Limit CLM3 HIGH Limit Counting result You will hear buzzer dy on Print out date day Date dy oFF Do not print out date day ti on Print out time Time ti oFF Do not print out time LAoff Donotprintoutlabelcaption Label LAon Printoutlabelcaption dFno Defaultsettingisreleased Default dF YES Everything is setup in default ItalicBold DefaultSetting Select the DEP printer in the ...

Страница 21: ...PRINT keytohave numberupordown Toenter nextdigit pressthe SAMPLE key PresstheSETkeytosave dysave isshownonthe displayandthenthedisplay showsadayoftheweek Ifyou setupadayoftheweekwrong dyerr isshownonthedisplay Youcanchangethedayby pressingtheHOLD or PRINT key Ifyousetup adayoftheweekwrong Wkerr isshownonthedisplay PresstheSETkeytosave Wksave isshownonthe display Ifyoudonotwanttosave presstheZEROke...

Страница 22: ...ntedout Ifyoudonotwanttoprintouttime presstheHOLD key PresstheSAMPLE key tosetuptime 00 00 00 isshownonthedisplay PresstheHOLD or PRINT keytohave numberupordown Toenter nextdigit pressthe SAMPLE key PresstheSETkeytosave tisave isshownonthe display Ifyoudonotwanttosavetime presstheZEROkey ...

Страница 23: ... PresstheSAMPLE key WELCOMTOCAS isshown onthedisplayindefault YoucanprogramlabelcaptionbypressingHOLD or PRINT key Toenternextdigitorpreviousdigit press theMODEorSAMPLE key YoucanenteralphabetorspecialcharacterbypressingtheTAREkey Whenyouenterspecial character STABLElampison Whenyouenteralphabet STABLElampisoff PresstheSETkeytosave LAsave isshownonthedisplay Ifyoudonotwanttosave presstheZEROkey ...

Страница 24: ...elast spancalibration PleasecallyourCASdealer Err3 The Err3 isanoverloaderror Pleaseremovetheweight Err 9 The Err 9 is no weight error When scale is in counting mode you must load the weight If you have no weight on your scale you can see this error message Please load the weight on your tray Err14 The Err14 meanscalibration rangeisnotcorrect PleasecallyourCASdealer SERIAL INTERFACE ...

Страница 25: ... 95kg 5 998lb 14 995lb 29 99lb 59 98lb 149 5lb 299 9lb MAXTARE 2 999g 5 998g 14 995g 29 990g Notuse Notuse INTERNAL RESOLUTION 1 60 000 1 60 000 1 60 000 1 60 000 1 60 000 1 60 000 EXTERNAL ESOLUTION DUAL1 3 000 DISPLAY LCD6digits DISPLAYLAMP STABLE ZERO HOLD NET HI OK LO lb oz PCS SUM kg LowBattery INTERFACE RS 232C DEP50 DLP50 POWERSOURCE DC12V1 25A Adaptor 6V3 3AHPbBattery TEMPERATURE RANGE 10 ...

Страница 26: ...t pipe to the post bracket Refer to fig 1 4 Fasten the post pipe with two bolts Refer to fig 1 A long bolt should be connected to the upper side 5 Insert the wire to the post pipe Refer to fig 2 3 6 If the scale is not properly level please adjust 4 leg adjusting bolt at the bottom of the scale so as to center the bubble of the leveling gauge Note Place the scale on a flat and stable surface Insid...

Страница 27: ...f grand wire and load cell wire to load cell connector at thebackside of display as shown in Figure 2 3 Fasten grand wire to the bottom of platform body with bolt as shown in Figure 3 LOAD CELL WIRE MACHINE SCREW FH M4 10 4EA GROUND WIRE HEAD BRACKET MACHINESCREW PHM6 10 1EA GROUNDWIRE WASHER FLAT 6 1EA LOADCELLWIRE FIG 1 FIG 1 FIG 1 MODEL DB II Series ...

Страница 28: ...29 MEMO ...

Страница 29: ...30 MEMO ...

Страница 30: ...31 MEMO ...

Страница 31: ...32 ...

Отзывы: