31
Menu-GEN.15: Set average hold time
Function
Set average hold time
Set Range
(1 ~ 99)
Display Part
Meaning
HD-T. XX
Initial Value :
30 x 0.1 sec
When the weight change width changes within the automatic hold
range setting value, auto hold operation after set value x 0.1 second.
Menu-GEN.16: Set Auto Hold Range
Function
Set auto hold range
Set Range
(5 ~ 50)
Display Part
Meaning
AH-S. XX
Initial Value :
10 x 1 Digit
Auto hold operation when weight change width is less than
set value. x 1 digit.
Menu-GEN.17: Set Auto Hold Canceling Range
Function
Set auto hold canceling range
Set Range
(2 ~ 99)
Display Part
Meaning
AH-R. XX
Initial Value :
10 %
Auto hold cancel when weight change width is larger than
set value
Menu-GEN.18: Set the use of set key.
Function
Set the use of set key
Set Range
(0 ~ 6)
Display Part
Meaning
FKEY.00
Set key used as the hold key.
FKEY.01
Set key used as the total print key.
FKEY.02
Set key used as the start key.
FKEY.03
Set key used as the tare clear key.
FKEY.04
Set key used as the hold clear key.
FKEY.05
Set key used as the Set Point key.
FKEY.06
Set key used as the Print key.
Menu-GEN.19: Set the use of print key.
Function
Set the use of print key
Set Range
(0 ~ 6)
Display Part
Meaning
PKEY.00
Set key used as the hold key.
PKEY.01
Set key used as the total print key.
PKEY.02
Set key used as the start key.
PKEY.03
Set key used as the tare clear key.
PKEY.04
Set key used as the hold clear key.
PKEY.05
Set key used as the Set Point key.
PKEY.06
Set key used as the Print key.