18
CALIBRATION MODE
(1) How to Enter
Turn on the power while pressing “NET/GROSS” key on the front of the indicator.
(2) Calibration Menu(CAL 1 - CAL 9)
CAL 1: Maximum capacity set
CAL 2: Minimum division set
CAL 3: Zero & Span calibration
CAL 5: Direct calibration
CAL 6: Zero adjustment
CAL 7: Factor calibration
CAL 8: Gravity adjustment
CAL 9: Setting dual range
CAL 1
CAL 1-1
FUNCTION : Set Unit
Set Unit : kg, ton
KEY
DISPLAY
DESCRIPTION
▲,
▼
Key : Value change
ZERO Key : Cancel
SET Key : Save and next menu
kg
Unit : kg
ton
Unit : ton
CAL 1-2
FUNCTION : Setting Maximum Value
Range of set value : 1 ~ 99,999
KEY
DISPLAY
DESCRIPTION
▲ Key : Value change
◀
Key : Digit change
ZERO Key : Cancel
SET Key : Save and next menu
Max value = 5000 kg
Max value = 20000 kg
► Note 1. It means the maximum weight value to be weighed by the scale.
Содержание CI-170A
Страница 1: ...2 ...
Страница 3: ...4 ...
Страница 4: ...5 ...
Страница 8: ...9 MEASURE OF APPEARANCE ...
Страница 76: ...77 MEMO ...
Страница 77: ...78 MEMO ...
Страница 78: ...79 MEMO ...
Страница 79: ...80 ...