9
8
KEY FUNCTION(LCD TYPE)
Remote Control(LED TYPE)
ON/OFF: Button to save battery life while
pause in operating condition.
ZERO: Button to correct zero value.
TARE: Used to tare value memorizing.
HOLD: Used to weigh moving thing.
Notice: Power ON / OFF function of the scale
itself: use only main ON / OFF switch.
ON
OFF
ZERO
TARE
HOLD
LAMP
Used for ON or OFF the power.
Brings the display to “0” while drifted.
This key is used to preset tare weight and subtract or clear the tare
weight.
Used to weigh moving things.(Manual / Automatic)
This back light used as a light while the scale used in dark area.
KEYS
FUNCTIONS
OPERATIONS
1. INSTALLATION
1
2
3
BODY
LOADCELL
HOOK
LOAD PIN
SAFETY PIN
Tighten the Load Cell and
the Hook and then insert
pin into the hole in Hook.
Fix the pin with a safety
pin.
Fold the safety pin to
tighten it.
2. BATTERY COUPLING
Couple connector in main body with connector in battery portion.
Insert battery portion to the main body and turn fixing bolt to the right to fix.
BATTERY
FIXING BOLT
BODY
Содержание CASTON II
Страница 1: ...CASTON Crane Scale OWNER S MANUAL ...
Страница 8: ...14 MEMO ...