CAUTION
Motor must be
phased to ensure
proper rotation
PHASING THE MOTOR
•
3 Phase motors are capable of running in both
forward and reverse, so the pump can pump
water both directions.
•
If wired incorrectly, the pump will run in the
reverse direction, pumping little water.
Continuously running the pump in
reverse will cause premature motor
failure that is not covered by warranty.
•
When wired correctly, there will be a
measurable increase in the amount of
water pumped.
•
Swapping any two red, yellow, or black wire
connections will reverse the direction the
motor is running.
•
When in doubt, reverse any two red, yellow,
or black wire connections and compare the
water flow to determine the correct wiring
configuration.
Carry Pumps, Inc.
·
1360 Prospect Ave.
·
Caro, MI 48723
www.carrypumps.com
·
800
-
492
-
2779
·