background image

 

5

 

 

Note:

 

 

                                                       

 

 
 

 

is

 

shown

 

if

 

the

 

weather

 

forecast

 

is

 

Rainy

 

OR

 

Cloudburstand

 

and

 

outdoor

 

temperature

 

under

 

0

°

C.

 

z

 

If

 

there

 

is

 

any

 

inconsistency

 

of

 

weather

 

forecast

 

between

 

Local

 

Weather

 

Station

 

and

 

this

 

unit,

 

the

 

Local

 

Weather

 

Station's

 

forecast

 

should

 

prevail.

 

We

 

will

 

not

 

hold

 

responsible

 

for

 

any

 

trouble

 

that

 

may

 

come

 

up

 

due

 

to

 

wrong

 

forecasting

 

from

 

this

 

unit.

 

 

7.

   

Barometric

 

Pressure

 

Reading

 

Press

 

“button

 

(B7)

 

to

 

select

 

the

 

barometric

 

pressure

 

readout

 

in

 

inHg

 

or

 

mb/hPa

 

7.1

 

 

Barometric

 

Trend

 

Pointer

 

(A9)

 

The

 

trend

 

pointer

 

displayed

 

on

 

the

 

LCD

 

(A9)

 

indicates

 

the

 

trend

 

of

 

the

 

Barometric

 

pressure.

 

 

 

Indicating

 

the

 

barometric

 

pressure

 

trend

 

is

 

rising

 

 

 

Indicating

 

the

 

barometric

 

pressure

 

trend

 

is

 

steady

 

 

 

Indicating

 

the

 

barometric

 

pressure

 

trend

 

is

 

falling

 

 

 

7.2

 

Absolute

 

/

 

Relative

 

Air

 

Pressure

 

z

 

Press

 

the

 

“REL/ABS”

 

button

 

[B5]

 

to

 

toggle

 

between

 

Absolute

 

or

 

Relative

 

pressure

 

display.

   

Abs

 

is

 

shown

 

for

 

Absolute

 

Pressure;

 

Rel

 

is

 

shown

 

for

 

Relative

 

pressure

 

z

 

Absolute

 

pressure

 

is

 

the

 

actual

 

pressure

 

measured

 

by

 

the

 

Main

 

Unit

 

z

 

Hold

 

“REL/ABS/WEATHER”

 

button

 

[B5]

 

for

 

3

 

seconds,

 

to

 

set

 

the

 

current

 

weather

 

forecast

 

firstly.

 

Once

 

the

 

current

 

weather

 

forecast

 

icon

 

is

 

set

 

and

 

confirmed,

 

the

 

relative

 

air

 

pressure

 

digit

 

will

 

begin

 

to

 

flash.

 

Press

 

 

(B7)

 

or

 

+

 

“(B6)

 

button

 

to

 

set

 

the

 

local

 

relative

 

air

 

pressure,

 

and

 

press

 

“REL/ABS/WEATHER”

 

button

 

(B5)

 

to

 

confirm.

 

Note:

 

Check

 

your

 

local

 

weather

 

station

 

for

 

Sea

 

Level

 

pressure

 

information

 

 

7.3

 

Barometric

 

Pressure

 

Bar

 

Graph

 

The

 

Barometric

 

Pressure

 

Reading

 

at

 

0hr,

 

–1hr

 

(pressure

 

one

 

hour

 

ago),

2hr

 

(pressure

 

2

 

hours

 

ago),

3hr,

6hr,

  ‐

12hr,

24hr,

  ‐

30hr

 

is

 

recorded

 

and

 

shown

 

on

 

Barometric

 

Pressure

 

Bar

 

Graph

 

[A12].

 

The

 

Graph

 

is

 

displayed

 

in

 

both

 

hPa

 

and

 

inHg

 

 

Freezing or Snow 

 

Содержание KW9005W-SM

Страница 1: ...ico Moon Phase display Perpetual Calendar Up to Year 2099 1 3 Barometric Pressure Current and past 30hr Absolute and Relative Barometric Pressure reading Barometric Pressure bar chart Measures mb hPa inHg user selectable 1 3 Humidity Measurable range 20 99 Max Min Memory 1 4 Temperature Indoor measurable range 0 50 C 32 122 F Measures C F user selectable Outdoor measurable range 20 50 C 4 122 F Ma...

Страница 2: ...re Reading A12 Barometric Pressure Bar Graph A13 Beaufort scale A14 Wind Speed A15 Wind Chill A16 Indoor Temperature A17 Indoor Humidity A18 Channel A19 Outdoor Temperature A20 Outdoor Humidity 2 2 Part B Buttons B1 SNOOZE LIGHT button B2 AL ON OFF button B3 SUN MOON button B4 MODE SET button B5 REL ABS WEATHER button B6 C F button B7 inHg hPa button B8 WIND CHILL GUST button B9 RESET button B10 C...

Страница 3: ...in Unit z Open main unit battery compartment cover C2 z Insert 3 x AA batteries observing polarity and marks z Replace main unit battery compartment cover C2 z Use a pin to press the RESET B9 button on the rear of the main unit the main unit is now ready for use 4 2 Outdoor Remote Sensor Wind Sensor z Batteries compartment D7 of thermo sensor is locating behind the back cover unscrews the batterie...

Страница 4: ... 6 1 Operation z After Batteries inserted or holding WEATHER button B5 for 3 seconds weather icon flash A10 on the LCD Enter the current weather pressing B7 or B6 button Press WEATHER B5 button to confirm the setting The weather forecast may not be accurate if the current weather entered is not correct z The current weather status should be entered again if the altitude of the Main Unit is changed...

Страница 5: ...is falling 7 2 Absolute Relative Air Pressure z Press the REL ABS button B5 to toggle between Absolute or Relative pressure display Abs is shown for Absolute Pressure Rel is shown for Relative pressure z Absolute pressure is the actual pressure measured by the Main Unit z Hold REL ABS WEATHER button B5 for 3 seconds to set the current weather forecast firstly Once the current weather forecast icon...

Страница 6: ... show the minimum recorded Indoor Outdoor Temperature and Humidity MIN is shown on the LCD z Hold MAX MIN button B4 for 3 seconds to clear the recorded outdoor maximum and minimum reading 2 Celsius Fahrenheit z Press C F button B6 to select Indoor Outdoor Temperature in Celsius mode or Fahrenheit mode z Press the C F button D8 on the rear thermo sensor inside the battery compartment to select the ...

Страница 7: ... synchronize with the WWVB radio signal at 3 00 am 4am and 5am z The clock can be set to scan the radio signal manually by holding button B13 for 3 seconds Each reception takes several minutes If the WWVB signal reception fail scanning stops disappear from the LCD and the clock then attempt to scan the radio signal again on next full hour E g scanning failed at 8 20a m it will scan again at 9 00a ...

Страница 8: ...Alarm Time 2 press AL ON OFF B2 button to switch that alarm ON or OFF If it is on alarm icon or will be shown on the LCD z When Alarming press SNOOZE button B1 to activate the snooze alarm alarm icon or flashes on LCD The alarm will snooze for approximately 5 minutes then it alarms again z Press any of SUN MOON B3 MODE SET B4 ALARM ON OFF B5 12 24 B7 or B8 button to stop the snooze alarm Otherwise...

Страница 9: ... exact Sunrise Sunset and Moonrise Moonset time please refer to your Local Weather Station Note During Daylight Saving Time in Canada and the USA select DST mode manually to adjust the sunrise and sunset times 1 Hold button B11 for 3 seconds to select DST mode or exit DST mode 2 If in DST mode DST icon would be display on the LCD and the current SUNSET SUNRISE times would be adjusted 1 hour accord...

Страница 10: ...sting from this unit Countries and Cities there are 3 countries can be chosen from the Time Setting Mode They are listed in the following table USA USA Iowa IA Mississippi MS Alaska AK Waterloo ALO Greenwood GWO Juneau JNU Des Moines DSM Huntsville HUV Alabama AL Davenport DVN Jackson JAN Birmingham BHM Sioux City SUX Tupelo TUP Gadsden GAD Idaho ID Montana MT Montgomery MGM Boise BOI Billings BIL...

Страница 11: ...altimore BWI Magdalene MAG Washington DCA Maine ME Roswell ROW Delaware DE Augusta AUG Raton RTN Dover 0N5 Bangor BGR Santa Fe SAF Florida FLG Caribou CAR Nevada NV Key West EYW Portland PWM Austin AIN Jacksonville JAX Michigan MIA Carson City CXP Miami MIA Kalamazoo AZO Ely ELY Orlando ORL Detroit DET Las Vegas LAS Pensacola PNS Flint FNT Wells LWL Tallahassee TLH Lansing LAN Reno RNO Tampa TPA R...

Страница 12: ...stone WYE Pittsburgh PIT Richmond RIC Canada CAN Scranton SCR Roanoke ROA Calgary CAL Puerto Rico PR Vermont VT Charlotte Town CHT San Juan SJU Burlington BTV Edmonton EDM Rhode Island RI Montpelier MPR Fredericton FRE Providence PVD Washington WA Halifax HAL South Carolina SCR Aberdeen ABE Montreal MON Charleston CHS Walla Walla ALW Ottawa OTT Columbia CUB Kettle Falls KTF Quebec QUE Greenville G...

Страница 13: ...ge 0 to 50 C 32 to 122 F Temperature Units Measured C or F switchable Humidity Range 20 to 99 Air Pressure Range 850 1050 hPa Air Pressure Units Measured mb hPa inHg switchable Weather Forecast 5 icons sunny slightly cloudy cloudy rainy cloudburst Outdoor Data Transmission distance open area 30m 433MHz Temperature range 20 C to 50 C 4 to 122 F Mount wall table Main Unit Dimensions W118 x h200 x d2...

Страница 14: ...the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly ap...

Отзывы: