5–3
62-11637
3. The hour meter screen will display with a 15 second timeout. Press the Arrow keys to scroll through the
available selections. With the desired sub-menu highlighted, Press the “=” key to view the data.
4. The number of meters displayed depends on the settings for this unit. Press the BACK key to return to the
HOUR METERS screen or the EXIT key to return to the default screen. Once activity requiring use of Tech-
nician Mode is complete, Technician Mode should be manually canceled, refer to
5.2.2
Inactive Alarms
There are two sections in the Alarm list: an active alarm section and an inactive alarm section. The control system
can hold up to 16 alarms in the combined lists. The lists can be read via the display screen or using TRU-Tech.
Alarms in these sections are in the order in which the alarms activate and inactivate, respectively. On startup, all
alarms are moved to the inactive list. If an inactive alarm becomes active, the alarm is moved from the inactive list
to the active list.
Each alarm can only be present in either the active or inactive list at any given time. As conditions change, alarms
may be moved from the active list to the inactive list and back.
Alarms are also recorded in the DataLink data recorder. They are recorded at the time they occur (become active),
and the time they become inactive.
Instructions for reading and clearing the Inactive Alarms are provided in
. For a complete list of Alarms
and troubleshooting information Refer to
NOTE
The Inactive Alarm List is also called the Technician’s List. Only qualified refrigeration technicians
should access the inactive list. It is not intended for the use of drivers or Advanced Users.
Figure 5.3 Inactive Alarms
STANDARD HOUR METERS
BACK
EXIT
Engine Hours
Switch On Hours
Total Run Hours
1060 Hours
1400 Hours
1182 Hours
END OF LIST
MAINTENANCE METERS
BACK
EXIT
Time Left to (Meter Name) #####
END OF LIST
OTHER METERS & COUNTERS
BACK
EXIT
Meter/Counter List
END OF LIST
Engine Protect Hours
Switch On Protect Hours
Engine Sleep Hours
Switch On Sleep Hours
High Speed Hours
Clutch Cycles
Start Cycles
High Speed Hours
Start Cycles
Switch On Hours
Engine Hours
As Configured
Number of Hours
or Cycles.
RESET PM HOUR METERS (1 OF 2)
BACK
EXIT
END OF LIST
RESET
Time Left to Engine Hours 0
Time left to Switch On Hours 0
To reset an hour meter, highlight it and then press
the RESET soft key. In this example, the Switch On
meter would be reset.
Clutch Cycles
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
ACTIVE ALARMS (2 of 5)
CLEAR
ALARMS
BACK
A00013 High Discharge Pressure
A00022 Low Suction Superheat
A00028 Check Refrig System
ACTIVE ALARMS
CLEAR
ALARMS
No Active Alarms
BACK
INACTIVE
ALARMS
INACTIVE ALARMS
CLEAR
INACTIVE
I00093 Check Start
ï
up Buzzer
P00170 Check LIV circuit
P00141 Pretrip Stopped By User
EXIT
CLEAR
ALL
BACK
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
ACTIVE ALARMS (2 of 5)
CLEAR
ALARMS
BACK
A00013 High Discharge Pressure
A00022 Low Suction Superheat
A00028 Check Refrig System
ACTIVE ALARMS
CLEAR
ALARMS
No Active Alarms
BACK
INACTIVE
ALARMS
1
2
5
6