3
Physical data
* Tube sizes are for runs up to 100 ft. Maximum tube set length is 100 ft.
NOTE:
See unit Installation Instructions for proper installation.
Accessories
Accessory description and usage (Listed alphabetically)
1.
Filter Drier — Bi-flow
A device for removing contaminants from refrigerant circulating in a heat pump system: 2-direction flow.
SUGGESTED USE: Split-system heat pumps.
2.
Snow Stand
Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base.
SUGGESTED USE: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
3.
Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base;
minimizes corrosion.
SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
4.
Thermostatic Expansion Valve (TXV) — Bi-Flow
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RBP valves are available.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning applications.
UNIT SIZE-SERIES
036-30
048-30
060-30
OPERATING WEIGHT (Lb)
316
316
318
REFRIGERANT
22
Cooling Control
TXV
Heating Piston
57
70
70
CHARGE (Lb)
15.6
14.6
14.4
COND FAN
Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM) — High Speed
2650
3200
COND COIL
Face Area (Sq Ft)
Copper Tube, Aluminum Plate Fin
18.0
VALVE CONNECT. (In. ID)
Vapor
Liquid
Sweat
7/8
3/8
REFRIG TUBES*
(In. OD)
Vapor
Liquid
7/8
1-1/8
3/8
ORDERING
NUMBER
DESCRIPTION
KHASS0206MPK
Snow Stand
KSASF0101AAA
Support Feet (4)
KHATX1501HSO
Thermostatic Expansion Valve (Required)
P504-8163S (RCD)
Filter Drier — Bi-flow
THERMOSTAT AND SUBBASE
DESCRIPTION
TSTATCCN2S01-A
Carrier Thermostat, Auto Changeover, Non-Programmable,
°
F/
°
C, 2-stage heat/2-stage cool in AC mode,
3-stage heat/2 stage cool in HP mode
TSTATCCP2S01-A
Carrier Thermostat, Auto Changeover, 7-Day Programmable,
°
F/
°
C, 2-stage heat/2-stage cool in AC mode,
3-stage heat/ 2-stage cool in HP mode
TSTATCCSEN01
Outdoor Sensor