Detailed cooling capacities* continued
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length
and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80
°
F (27
°
C) entering air at the indoor coil. For sensible capacities at other than 80
°
F (27
°
C), deduct
835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80
°
F (27
°
C), or add 835 Btuh (245
°
kw) per 1000 CFM
(480 L/S) of indoor coil air per degree above 80
°
F (27
°
C). When the required data falls between the published data, interpolation may be
performed.
** Unit kw is total of indoor and outdoor unit kilowatts.
†† Sensible capacity multipliers are based on the rated airflow of the listed indoor section. Refer to the airflow listed in the ‘‘Ratings and
Performance’’ table.
‡‡ At TVA rating indoor condition (75
°
EDB/63
°
EWB). All other indoor air temperatures are at 80
°
EDB.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES
°
F
85
95
105
115
CFM
EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
38YDA060-30 Outdoor Section in Low-Speed With FK4CNB006 Indoor Section
1115
72
36.5
19.6
2.05
34.7
19.0
2.42
32.8
18.3
2.77
30.8
17.6
3.08
67
33.2
25.3
2.14
31.5
24.6
2.48
29.7
23.9
2.78
27.8
23.1
3.06
63‡‡
30.9
24.4
2.20
29.2
23.7
2.51
27.4
23.0
2.78
25.6
22.2
3.03
62
30.5
30.5
2.20
29.2
29.2
2.50
27.8
27.8
2.78
26.3
26.3
3.04
57
28.9
28.9
2.23
29.2
29.2
2.49
29.5
29.5
2.79
29.9
29.9
3.10
1240
72
37.0
20.5
2.05
35.1
19.9
2.43
33.2
19.2
2.78
31.1
18.5
3.10
67
33.7
26.8
2.15
32.0
26.1
2.49
30.1
25.4
2.80
28.2
24.6
3.08
63‡‡
31.3
25.8
2.21
29.6
25.1
2.52
27.8
24.3
2.80
25.9
23.6
3.06
62
31.5
31.5
2.20
30.1
30.1
2.51
28.6
28.6
2.80
27.1
27.1
3.07
57
32.5
32.5
2.17
32.9
32.9
2.48
32.9
32.9
2.80
32.9
32.9
3.15
1365
72
37.3
21.4
2.06
35.5
20.8
2.44
33.5
20.1
2.80
31.4
19.4
3.12
67
34.1
28.2
2.15
32.3
27.5
2.50
30.5
26.8
2.82
28.5
26.1
3.11
63‡‡
31.7
27.2
2.22
30.0
26.5
2.53
28.1
25.7
2.82
26.2
24.9
3.08
62
32.4
32.4
2.20
30.9
30.9
2.52
29.4
29.4
2.82
27.8
27.8
3.10
57
35.9
35.9
2.12
35.9
35.9
2.47
36.0 36.0
2.82
35.7
35.7
3.18
1500
72
37.7
22.3
2.07
35.8
21.7
2.46
33.8
21.1
2.82
31.6
20.4
3.14
67
34.5
29.8
2.16
32.7
29.1
2.52
30.8
28.3
2.84
28.8
27.5
3.13
63‡‡
32.0
28.6
2.23
30.3
27.9
2.55
28.4
27.1
2.85
26.6
26.1
3.11
62
33.2
33.2
2.20
31.7
31.7
2.53
30.1
30.1
2.84
28.5
28.5
3.13
57
39.0
39.0
2.06
38.8
38.8
2.45
38.5
38.5
2.83
37.8
37.8
3.23
1625
72
37.9
23.2
2.08
36.0
22.6
2.47
34.0
21.9
2.83
31.8
21.2
3.16
67
34.8
31.1
2.17
33.0
30.4
2.53
31.1
29.6
2.86
29.1
28.7
3.15
63‡‡
32.3
29.9
2.24
30.6
29.1
2.57
28.7
28.2
2.86
26.9
26.9
3.14
62
33.8
33.8
2.20
32.3
32.3
2.54
30.7
30.7
2.86
29.0
29.0
3.15
57
41.4
41.4
2.00
41.1
41.1
2.42
40.5
40.5
2.84
39.3
39.3
3.24
1750
72
38.1
24.1
2.09
36.2
23.4
2.48
34.2
22.8
2.85
32.0
22.1
3.18
67
35.0
32.4
2.18
33.3
31.7
2.55
31.4
30.8
2.88
29.5
29.5
3.18
63‡‡
32.6
31.1
2.25
30.9
30.2
2.58
29.1
29.1
2.89
27.4
27.4
3.16
62
34.4
34.4
2.20
32.9
32.9
2.55
31.2
31.2
2.88
29.5
29.5
3.18
57
43.4
43.4
1.96
42.8
42.8
2.40
41.9
41.9
2.84
40.0 40.0
3.25
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Sensible††
Power
Capacity
Sensible††
Power
F(A,B)4AN(F,B)
060
1.00
1.00
1.29
CJ5A/CK5A/CK5BX
060
0.97
0.87
1.00
FB4ANB
070
1.00
1.00
1.23
CK3BA
060
0.96
0.86
1.01
FC4BN(F,B)
060
1.00
1.00
1.29
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
FC4BNB
070
1.00
1.00
1.23
CC5A/CD5A/CD5BA
060
0.94
0.86
1.00
FK4CNB
006
1.00
1.00
1.00
CC5A/CD5A/CD5BW
060
0.96
0.89
0.99
CC5A/CD5A/CD5BA
060
0.94
0.85
1.10
CD3(A,B)A
060
0.94
0.86
1.00
CC5A/CD5A/CD5BW
060
0.96
0.88
1.09
CD3CA
060
0.94
0.89
0.99
CD3(A,B)A
060
0.94
0.85
1.10
CE3AA
060
0.96
0.91
0.99
CE3AA
060
0.96
0.90
1.10
CJ5A/CK5A/CK5BA
060
0.96
0.94
1.01
CJ5A/CK5A/CK5BA
060
0.94
0.92
1.12
CJ5A/CK5A/CK5BX
060
0.98
0.95
1.00
CJ5A/CK5A/CK5BN
060
0.96
0.94
1.11
CK3BA
060
0.96
0.94
1.01
CJ5A/CK5A/CK5BX
060
0.96
0.94
1.11
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CK3BA
060
0.94
0.92
1.12
CC5A/CD5A/CD5BA
060
0.94
0.85
1.00
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BW
060
0.96
0.88
0.99
CC5A/CD5A/CD5BA
060
0.94
0.80
1.00
CD3(A,B)A
060
0.94
0.85
1.00
CC5A/CD5A/CD5BW
060
0.94
0.82
0.98
CD3CA
060
0.94
0.88
0.99
CD3(A,B)A
060
0.94
0.80
1.00
CE3AA
060
0.96
0.90
0.99
CE3AA
060
0.94
0.84
0.99
CJ5A/CK5A/CK5BA
060
0.96
0.92
1.02
CJ5A/CK5A/CK5BA
060
0.96
0.86
1.01
CJ5A/CK5A/CK5BX
060
0.98
0.94
1.01
CJ5A/CK5A/CK5BN
060
0.97
0.87
1.01
CK3BA
060
0.96
0.92
1.02