![Carrier PrimeLINE 69NT40-561 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/carrier/primeline-69nt40-561/primeline-69nt40-561_inspection-manual_2563854018.webp)
62-10327
14
8. Examine the flexible condensate defrost drain tube (Refer to
). The tube should be undamaged and free from
blockage or debris. It may be necessary to remove the condenser
fan for complete access.
Figure 17 Condensate Defrost Drain Tube
9. Examine external valves, coils, sight glasses, pressure
transducers as equipped per the unit model number checking for
physical damage, leaks or corrosion. Clean, repair or replace as
necessary. Refer to the
for details on
equipped valves. Locating operation & service manuals is
explained in the
section.
10. Inspect filter/drier for excessive corrosion or physical damage, and
). Periodic paint touch up of
the filter may be required.
Figure 18 Filter/Drier
Model/Serial Number plate
Flexible condensate defrost drain tube
Содержание PrimeLINE 69NT40-561
Страница 2: ......
Страница 4: ......
Страница 8: ...62 10327 4 Figure 3 Evaporator Coil Figure 4 Evaporator Fan Blade...
Страница 11: ...7 62 10327 Figure 9 ETS1 and ETS2 Figure 7 TXV Figure 8 EEV...
Страница 17: ...13 62 10327 Figure 15 Flat Condenser Coil Figure 16 C Condenser Coil Flat condenser coil C condenser coil...
Страница 26: ......
Страница 28: ......
Страница 29: ......