PRODUCT DAMAGE HAZARD

Failure to follow this caution may result in product or property

damage.
Wrap a wet cloth around rear of fitting to prevent damage to

TXV and factory--made joints

.

CAUTION

!

Step 6 — Refrigerant Flow--Control Device

The PF4MNB fan coil is equipped with R--410A refrigerant TXV.

Use outdoor units designed for R--410A refrigerant only.

PRODUCT OPERATION HAZARD

Failure to follow this caution may result in improper product

operation.
If using a TXV in conjunction with a single--phase

reciprocating compressor, a compressor start capacitor and

relay are required. Consult outdoor unit pre--sale literature for

start assist kit part number.

CAUTION

!

Step 7 — Condensate Drains

To connect drains, the cap openings must be removed. Use a knife
to start the opening near the tab and using pliers, pull the tab to

remove the disk. Clean the edge of the opening if necessary and

install the condensate line. Finally caulk around the lines where
they exit the fitting to retain the low leak rating of the unit.

UNIT OR PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in product or

property damage.
The conversion of the fan coil to downflow requires special

procedures for the condensate drains on both A--coil and

slope units. The vertical drains have an overflow hole

between the primary and secondary drain holes. This hole is

plugged for all applications except downflow, but must be

used for downflow. During the conversion process, remove

the plastic cap covering the vertical drains only and discard.

Remove the plug from the overflow hole and discard. At

completion of the downflow installation, caulk around the

vertical pan fitting to door joint to retain the low air leak

performance of the unit.

CAUTION

!

Units are equipped with primary and secondary 3/4--in. FPT drain

connections. For proper condensate line installations see Fig. 1, 2,

3, 5 and 6. To prevent property damage and achieve optimum
drainage performance, BOTH primary and secondary drain lines

should be installed and include properly--sized condensate traps.
(See Fig. 17 and 18.) Factory--approved condensate traps are

available. It is recommended that PVC fittings be used on the

plastic condensate pan. Finger--tighten plus 1--1/2 turns. Do not
over--tighten. Use pipe dope.

2” MIN

(51 mm)

UNIT

2” MIN

(51 mm)

A03002

Fig. 17 -- Recommended Condensate Trap

FILTER
ACCESS
PANEL

SECONDARY DRAIN WITH
APPROPRIATE TRAP REQUIRED
(USE FACTORY KIT OR
FIELD-SUPPLIED TRAP)

PRIMARY TRAP REQUIRED

(USE FACTORY KIT OR 

FIELD-SUPPLIED TRAP OF 

SUFFICIENT DEPTH. 

STANDARD P-TRAPS ARE 

NOT SUFFICIENT. SEE 

FIGURE OF RECOMMENDED 

CONDENSATE TRAP)

A03003

Fig. 18 -- Condensate Trap and Unit

PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in product or property

damage.
Shallow running traps are inadequate and DO NOT allow proper

condensate drainage. (See Fig. 19.)

CAUTION

!

DO NOT USE SHALLOW RUNNING TRAPS!

A03013

Fig. 19 -- Insufficient Condensate Trap

NOTE

: When connecting condensate drain lines, avoid blocking

filter access panel, thus preventing filter removal. After connection,
prime both primary and secondary condensate traps.

NOTE

: If unit is located in or above a living space where damage

may result from condensate overflow, a field--supplied, external
condensate pan should be installed underneath the entire unit, and a
secondary condensate line (with appropriate trap) should be run
from the unit into the pan. Any condensate in this external
condensate pan should be drained to a noticeable place. As an

PF4M

NB

Содержание PF4MNB 019

Страница 1: ...d with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death...

Страница 2: ...ng with an accessory base kit Use fireproof resilient gasket 1 8 to 1 4 in 3 to 6 mm thick between duct unit and floor UNIT OR PROPERTY DAMAGE HAZARD Failure to follow this caution may result in produ...

Страница 3: ...h condensate pan down See Fig 5 5 Attach coil to casing flange using coil mounting screw pre viously removed 6 Make sure the pan cap in the fitting door is properly seated on the fitting door to retai...

Страница 4: ...fan coil b If fan coil is against wall secure fan coil to wall stud using 1 8 in 3 mm thick right angle brackets Attach brackets to fan coil using no 10 self tapping screws and to wall stud using 5 1...

Страница 5: ...er plug from fan coil and connect male plug from heater to female plug from unit wiring harness See Electric Heater Installation Instructions For units without electric heater 1 Connect 208 230v power...

Страница 6: ...factory wired for 230v operation For 208v applications disconnect the black wire from the 230v terminal on transformer and connect it to the 208v terminal See Fig 15 2 3 0 C 2 0 8 BRN RED YEL BLK SEC...

Страница 7: ...p 5 Max 0 sec off delay electric heat airflow is same CFM as Tap 3 except 0 sec off delay high static applications see airflow tables for max airflow To change motor speeds disconnect the BLUE fan lea...

Страница 8: ...vertical pan fitting to door joint to retain the low air leak performance of the unit CAUTION Units are equipped with primary and secondary 3 4 in FPT drain connections For proper condensate line ins...

Страница 9: ...o Y and R to O heat pump only G energizes fan relay on PCB which completes circuit to indoor blower motor When G is de energized there is a 90 second delay before fan relay opens NOTE Speed taps 1 2 a...

Страница 10: ...33 Tap 1 1237 1206 1160 1121 1070 1013 PF4MNB 049 Tap 5 1757 1725 1693 1653 1614 1576 Tap 4 1664 1626 1593 1552 1517 1477 Tap 3 1664 1626 1593 1552 1517 1477 Tap 2 1459 1420 1379 1336 1298 1259 Tap 1...

Страница 11: ...0 016 0 027 0 038 0 049 0 059 031 0 049 0 059 0 070 0 080 037 0 055 0 064 0 073 0 081 043 0 049 0 056 0 063 0 070 049 0 038 0 043 0 049 0 054 0 059 061 0 027 0 031 0 035 0 039 0 043 Table 3 Electric H...

Страница 12: ...nstall a suction line filter drier in liquid line S POE oils absorb moisture rapidly Do not expose oil to atmosphere S POE oils may cause damage to certain plastics and roofing materials S Wrap all fi...

Отзывы: