39
24Vac
TR
3
4
EF1
EF
N1
N
EXH
OPEN
SR
ECONOMIZER IV
BOARD
BRN
ECONOMIZER MOTOR
RED
WHT
BLK
1
3
2
BLK
BLK
YEL
BLK
RED
OAT TEMP/
ENTHALPY SENSOR
Vac
24
+
-
SR+
AQ
SO+
SO
P
P1
T1
T
A
FREE COOL
B
C
D
2V
DCV
SET
DCV
10V
2V
MAX
DCV
10V
POS
MIN
2V
SET
EXH
10V
AQ1
2
5
1
TR1
COM
HOT
6
IAQ
7
(FIELD
ACCESSORY) REMOTE MIN POSITION POT
FIELD INSTALLED
IAQ SENSOR
1
2
REMOTE POT (135 Ohm)
620k
(FIELD ACCESSORY) ENTHALPY SENSOR
GRY
FIELD SPLICE
FIELD SPLICE
+
S
+
S
BLK
LALS
(NOT USED)
(NOT USED)
7
BLU
ORG
VIO
PNK
(NOT USED)
(NOT USED)
TAN
TO PWR EXHAUST
ACCESSORY
NOTES: 1. 620 OHM, 1 WATT 5% RESISTOR SHOULD BE REMOVED ONLY WHEN USING DIFFERENTIAL ENTHALPY OR DRY BULB. 2. IF A SEPARATE FIELD SUPPLIED 24V TRANSFORMER IS USED FOR THE IAQ SENSOR POWER SUPPLY, IT CANNOT HAVE THE SECONDARY OF THE TRANSFORMER GROUNDED. 3. FOR FIELD INSTALLED REMOTE MINIMUM POSITION POT, REMOVE BLACK WIRE JUMPER BETWEEN P AND P1 AND SET CONTROL MINIMUM POSITION POT TO THE MINIMUM POSITION. 4. FOR VERTICAL ECONOMIZER THE ECONOMIZER MOTOR CONNECTIONS ARE AS SHOWN.FOR HORIZONTAL ECONOMIZER THE ECONOMIZER MOTOR IS ATTACHED TO THE ECONOMIZER IV BOARD, (THE WIRES SHOWN ARE NOT UTILIZED --BLK, WHT
& RED)
5. WHEN NOT USING A CO2 SENSOR, THE DCV MAX POTENTIOMETER MUST BE COMPLETELY CLOSED (CCW) FOR THE MINIMUM POSITION POTENTIOMETER TO FUNCTION CORRECTLY.
POTENTIOMETER DEFAULTS SETTINGS: POWER EXHAUST MIDDLE MINIMUM POS. 1/4 OPEN DCV MAX. FULLY CLOSED DCV SET MIDDLE ENTHALPY C SETTING
PL6-R
FOR STD
UNIT
6
11
10
8
2
3
4
1
5
9
12
GRY
PINK
PINK
GRY
YEL
RED
BRN
BLK
R
EWG
O
Y1
Y
2
V
2-STAGE T-STAT
LOW
COM C
Y
IFB
BLU
BLU
SAT
YEL
WIRING FOR AC AND GAS/ELECTRIC MODELS
HPS
LPS
CC
BLK
BLU
BLK
BLU
BLOWER MOTOR BLK SPEEDTAB HIGH
RED
LEGEND
SPLICE
FACTORY WIRING
FIELD OR ACCESSORY CONTROL WIRING
C
48SD500120
C COMPRESSOR CONTACTOR DVC DEMAND CONTROLLED VENTILATION HPS HIGH PRESSURE SWITCH IAQ INDOOR AIR QUALITY SENSORS IFB INDOOR FAN BOARD LALS LOW TEMPERATURE COMPRESSOR LOCKOUT SWITCH LPS LOW PRESSURE SWITCH OAT OUTDOOR AIR TEMPERATURE SENSOR POT POTENTIOMETER SAT SUPPLY AIR TEMPERATURE SENSOR
SEE NOTE
4
A10098
Fig. 40 -- Economizer Wiring Diagram
50V
L
--
A
Содержание Performance 50VL-A
Страница 3: ...3 A09462 Fig 2 50VL A24 36 Unit Dimensions 50VL A ...
Страница 4: ...4 A09463 Fig 3 50VL A42 60 Unit Dimensions 50VL A ...
Страница 18: ...18 A10202 Fig 13 Connection Wiring Diagram 208 230 3 60 50VL A ...
Страница 19: ...19 A10202 Fig 13 Cont Ladder Wiring Diagram 208 230 3 60 50VL A ...
Страница 22: ...22 A09089 Fig 15 Cooling Charging Chart 50VL A ...
Страница 40: ...40 A10201 Fig 41 Connection Wiring Diagram 230 3 50VL A ...
Страница 41: ...41 A10201 Fig 41 Cont Ladder Wiring Diagram 230 3 50VL A ...
Страница 42: ...42 A10203 Fig 42 Connection Wiring Diagram 460 3 50VL A ...
Страница 43: ...43 A10203 Fig 42 Cont Ladder Wiring Diagram 460 3 50VL A ...