background image

9

CUT HAZARD

Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp

edges, be extremely careful when handling parts or reaching

into the furnace.

Wear safety glasses, gloves, and

appropriate protective clothing.

CAUTION

!

FILTERING OUT TROUBLE

NOTE

: The manufacturer has specified filters which will enable

your furnace to provide lasting comfort and efficiency throughout
its life. Contact your dealer to help you choose filters for your
furnace that both collect dirt before it enters your furnace, as well
as provide a low resistance to circulating air. Avoid filters that
report high cleaning efficiencies, but do not allow air to pass easily
through them.

UNIT PERFORMANCE HAZARD

Failure to follow this caution may result in unit component

damage.
Never operate your furnace without a filter in place. Doing

so may damage the furnace blower motor.

An

accumulation of dust and lint on internal parts of your

furnace can cause a loss of efficiency.

CAUTION

!

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.
Use care when cutting support rods in filters to protect against

flying pieces and sharp rod ends. Wear safety glasses, gloves,

and appropriate protective clothing.

CAUTION

!

A dirty filter will cause excessive stress on the furnace, heat
exchanger, and blower motor, and can cause it to overheat and

automatically shut down. The furnace filter should be checked
every four weeks and be cleaned or replaced if necessary.
If installed with factory--specified disposable media filter, check or
replace filter before each heating and cooling season. Replace

disposable media filter at least once a year.
If your furnace filter needs replacing, be sure to use the same size
and type of filter that was originally specified.
The air filter for the furnace may be located in an external filter
cabinet attached to the side or bottom of the furnace casing. If the

air filter has been installed in another location, contact your dealer

for instructions. To inspect, clean and/or replace the air filter(s),
follow these steps:

1. Turn off electrical supply to the furnace. See Fig. 20.
2. Remove air filter from the filter cabinet.

a. Remove filter cabinet door. (See Fig. 21 and 22.)

NOTE

: It may be necessary to remove one thumbscrew.
b. Slide air filter out of furnace. Keep dirty side up (if

dirty) to avoid spilling dirt.

3. Inspect the filter. If torn, replace it.

NOTE

: If a washable filter was supplied with the furnace and has

been replaced by:

S

Disposable media filter----Do not clean. If dirty, replace

only with media filter having the same part number and
size. Install with airflow direction arrow pointing to-

wards blower.

S

Electronic Air Cleaner (EAC), refer to the EAC Owner’s
Manual for maintenance information.

4. If washable filter, wash filter (if dirty) in a sink, bathtub, or

outside with a garden hose. Always use cold tap water. A

mild liquid detergent may be used if necessary. Spray water
through filter in the opposite direction of airflow. Allow fil-

ter to dry.

5. Reinstall clean air filter.
6. Turn on electrical supply to the furnace.

If your furnace air filter needs to be replaced, be sure to use a
factory--authorized filter of the same size that was originally

specified. Use the filter tables and compare your furnace size with

the proper filter size.

A92185

Fig. 20 -- Turn Off Electrical Supply

A00225

Fig. 21 -- Removal of Filter Cabinet Door from Side Blower

Cabinet

Содержание OM9GFC-03

Страница 1: ...d installer service agency or the gas supplier WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury and or death Carbon Monoxide is invisible odorles...

Страница 2: ...ay We are proud of the technological advances incorporated into the design of this furnace With only minimal care your new furnace will deliver many years of money saving home comfort and enjoyment Sp...

Страница 3: ...DELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY MEDIA CABINET OPERATING INSTRUCTIONS NOT SHOWN LOCATED ON MAIN FURNACE DOOR SEE OPERATING INSTRUCTIONS INSIDE DOOR FIG...

Страница 4: ...t vent 1 pipe Fig 3 application S In a direct vent 2 pipe application your furnace uses air from outside the home for combustion and vents flue gas to the outdoors This type of application will have t...

Страница 5: ...upply fail to shut off or if overheating occurs shut off the gas valve to the furnace before shutting off electrical supply This furnace contains SAFETY DEVICES which must be MANUALLY RESET If the fur...

Страница 6: ...ce be sure the furnace filter is clean and in place See Performing Routine Maintenance section in this manual Do not run the furnace without a filter in place Then proceed as follows STEPS FOR STARTIN...

Страница 7: ...heated for about 20 seconds the gas valve permits gas to flow to the main burners After igni tion and a time delay of up to 60 sec the furnace blower will start Variable capacity furnaces start at lo...

Страница 8: ...o OFF 6 Replace main furnace door See Fig 13 7 Ifthefurnaceisbeingshut downbecause ofa malfunction call your dealer as soon as possible UNIT AND PROPERTY DAMAGE HAZARD Failure to follow this caution m...

Страница 9: ...and cooling season Replace disposable media filter at least once a year If your furnace filter needs replacing be sure to use the same size and type of filter that was originally specified The air fi...

Страница 10: ...Air Filter Located in Filter Cabinet FILTER CABINET HEIGHT IN MM FILTER SIZE IN MM FILTER TYPE 16 406 1 16 x 25 x 3 4 406 x 635 x 19 or 1 16 x 25 x 4 5 16 406 x 635 x 110 Washable 20 508 1 20 x 25 x 3...

Страница 11: ...BON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury or death If dirt rust soot or scale accumulations are found call your dealer Do not operate your furnace WA...

Страница 12: ...urnace ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death Turn off electrical power supply to your furnace and install lockout tag before removing the acce...

Страница 13: ...ATING A11318 Fig 31 Operating Instructions Inside Door BEFORE YOU REQUEST A SERVICE CALL If your furnace is not operating or not performing properly you may save the expense of a service call by check...

Страница 14: ..._________________________________ INSTALLATION INFORMATION Date Installed ________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address___________...

Отзывы: