background image

6

Sample Furnace Circuit Board

Power Cord

to EAC Terminals

Alternate Power Cord 

Pass-Thru Hole

Use cable connector to secure

power cord to cabinet

Power Supply Connector

Power Supply

Use wire ties to secure power cord

to power supply enclosure

LHT
OFF
DLY

ON

OFF

W2

BLW

EAC-1 TERMINAL

Y1

DHUM

G

COM

24V

WW1

Y/Y2

R

TEST/TWIN

HUM

1  2  3

PL
T

A

CRDJ

0.5-AMP024 VAC

FUSE 3-AMP

SEC-1

SEC-2

PL1

NEUTRAL-L2

1

EAC-2

BHT/CLR

BHI/LOR

PL3       1

BLWR

COOL

SPARE-1

SPARE-2

1-AMP@115 VAC

EAC-1

PR-1

IDR

HSIR

IDM

IHI/LOR

PL2

1

HSI     HI    LO

STATU

S

C

OD

EL

E

D

EAC-2 TERMINAL

HI HEA

T

LO HEA

T

L1

Use terminals to connect the

power cord wires to the furnace

EAC-1 & 2, & ground terminals

Power Supply Connector

Power Cord

A06030

Fig. 7 -- Infinity

t

Air Purifier Electrical Connections

START--UP AND OPERATION

Step 1

Checking Air Purifier Operation

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

a. Attach the Infinity

t

Air Purifier door to the cabinet. A

magnet in the door (see Fig. 9) is used to activate a safe-

ty switch in the power supply when the door is installed.

The power supply will not energize the air purifier un-

less the safety switch is activated.

b. Turn the HVAC system power on and adjust the

thermostat or Infinity

t

System Control to activate the

system fan.

c. Turn the Infinity

t

Air Purifier power switch to on

position.

d. The power indicator light above the Air Purifier power

switch should illuminiate (see Fig. 8).

e. Check to ensure the light goes off when the Infinity

t

Air Purifier power switch is set to off, when the blower

goes off, or when the HVAC system power is turned off.

Step 2

Infinity Control

a. When the Infinity

t

Air Purifier is used with an Infinity

Control, the Infinity Control can be configured to

remind the homeowner when it is time to change the

Infinity

t

Air Purifier cartridge. This maintenance

reminder can be based on either the TrueSense

t

dirty

filter algorithm or time. The installer should use their

discretion to select the most appropriate option based on

the initial system static pressure.

Step 3

Maximizing Performance

a. Maximum air purification performance is obtained

when the furnace blower is set for continuous operation

on the thermostat or Infinity Control.

Power Indicator

A06052

Fig. 8 -- Power Indicator

MAINTENANCE

The Infinity

t

Air Purifier is designed to require no cleaning.

Maintenance is limited to the replacement of the air purification

cartridge. Frequency of air purifier cartridge replacement may

vary depending on ductwork design and local environmental

conditions.
To replace the air purifier cartridge, complete the following

steps:

Step 1

Turn the heating and cooling system off.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

GAP

A

Содержание INFINITY 1625

Страница 1: ...ee captured particles are killed by electrical current flow and ion bombardment A05265 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information ...

Страница 2: ... If the return air duct or furnace openings do not fit the Infinityt Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Infinityt Air Purifier is installed adjacent to a 90 degree duct elbow turning...

Страница 3: ... of the Infinityt Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinityt Air Purifier A thorough check of the unit installation should be compl...

Страница 4: ...net between the furnace and return air duct see Fig 3 and 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see ...

Страница 5: ...ly connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinityt Air Purifier is to be powered by 115v 60 Hz ...

Страница 6: ... system fan c Turn the Infinityt Air Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off when the blower goes off or when the HVAC system power is turned off Step 2 Infinity Control a When the Infinityt Air Purifier is used wi...

Страница 7: ...er indicator light located on the door see Fig 8 This power indicator light will illuminate when the Infinityt Air Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated follow the troubleshooting steps below Step 1 Check that the Infinityt Air Purifier door is installed NOTE Amagnet inthe door see Fig 9 i...

Страница 8: ...nace EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A05270 Fig 10 Di...

Страница 9: ...urned to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ...

Страница 10: ...10 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No GAPA 2SI Replaces GAPA 1SI Printed in China Edition Date 3 06 GAPA ...

Отзывы: