1

GAPA

Infinity

t

Air Purifier

Sizes 1625 and 2025

Installation, Start---Up, and

Operating Instructions

NOTE

: Read the entire instruction manual before starting the

install.

This symbol

indicates a change since the last issue.

TABLE OF CONTENTS

Page

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . .

INSTALLATION

3--5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

8

. . . . . . . . . . . . . . . .

WARRANTY

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Infinity

t

Air Purifier for your

home comfort system! The Infinity

t

Air Purifier is proven to

remove and kill airborne germs and allergens, including viruses,

bacteria, and mold spores. The Infinity

t

Air Purifier is a

cornerstone of Carrier’s Healthy Home Solutions for providing

healthier, cleaner air in your home.

HOW IT WORKS

The Infinity

t

Air Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Infinity

t

Air Purifier

treats the entire air--stream through a state of the art, three--stage

process, exclusive to Carrier.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the Infinity

t

Air

Purifier.
In stage two, the charged particles are electrically attracted to

the air purification cartridge, which is located within an electric

field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.

A05265

Fig. 1 -- GAPA Unit

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical shock

or other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The

qualified installer or agency must use factory authorized kits or

accessories when modifying this product. Refer to the

individual instructions packaged with the kits or accessories

when installing.
Follow all safety codes. Wear safety glasses and work gloves.

Have fire extinguisher available. Read these instructions

thoroughly and follow all warning or cautions attached to the

unit. Consult local building codes and National Electrical Code

(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words DANGER,

WARNING, and CAUTION. These words are used with the

safety--alert symbol. DANGER identifies the most serious

hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal

injury or death. CAUTION is used to identify unsafe practices

which

may

result in personal injury or product and property

damage. NOTE is used to highlight suggestions which

will

result in enhanced installation, reliability, or operation.

Содержание INFINITY 1625

Страница 1: ...ee captured particles are killed by electrical current flow and ion bombardment A05265 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information ...

Страница 2: ... If the return air duct or furnace openings do not fit the Infinityt Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Infinityt Air Purifier is installed adjacent to a 90 degree duct elbow turning...

Страница 3: ... of the Infinityt Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinityt Air Purifier A thorough check of the unit installation should be compl...

Страница 4: ...net between the furnace and return air duct see Fig 3 and 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see ...

Страница 5: ...ly connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinityt Air Purifier is to be powered by 115v 60 Hz ...

Страница 6: ... system fan c Turn the Infinityt Air Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off when the blower goes off or when the HVAC system power is turned off Step 2 Infinity Control a When the Infinityt Air Purifier is used wi...

Страница 7: ...er indicator light located on the door see Fig 8 This power indicator light will illuminate when the Infinityt Air Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated follow the troubleshooting steps below Step 1 Check that the Infinityt Air Purifier door is installed NOTE Amagnet inthe door see Fig 9 i...

Страница 8: ...nace EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A05270 Fig 10 Di...

Страница 9: ...urned to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ...

Страница 10: ...10 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No GAPA 2SI Replaces GAPA 1SI Printed in China Edition Date 3 06 GAPA ...

Отзывы: