2
INSTALLATION
Step 1 — Inspect Shipment —
Inspect unit for dam-
age upon arrival. If damage is found, immediately file a claim
with the shipping company. Verify proper unit delivery by
checking unit nameplate data and the model number nomen-
clature shown in Fig. 1. See Tables 1-6 for unit physical data.
Step 2 — Rig and Place Unit —
All units are de-
signed for overhead rigging, and it is
important that this meth-
od be used.
Lifting holes are provided in the frame base rails. It
is recommended to use shackles in the lifting holes (see rigging
label on the unit and Fig. 2 and 3 for rigging weights and center
of gravity). All panels must be in place when rigging.
Use spreader bars or frame to keep the cables, chains, and
straps clear of the unit sides.
Leave standard coil protection
packaging in place during rigging to provide protection to
coils. Remove and discard all coil protection after rigging ca-
bles are detached.
IMPORTANT: To maintain unit stability while lifting,
use 4 cables, chains or straps of equal length. Attach one
end of each cable to shackle attachment point and the
other end of each cable to the overhead rigging point.
CAUTION
All panels must be in place when rigging. Failure to com-
ply could result in equipment damage.
CAUTION
For unit sizes 018 to 060 when handling with a forklift,
handle only through fork pocket holes. Failure to follow
this caution could result in equipment damage or personal
injury.
CAUTION
For unit sizes 065 to 130, do not forklift the unit unless unit
is attached to a skid designed for forklifting. Failure to fol-
low this caution could result in equipment damage or per-
sonal injury.
09DP M 035 6 4 – 0 0 0 0 0
09DP –
Split System Condenser
Packaging/Security Options
0
– Std Packaging
4
– Security Grilles/Hail Guards Only
8
– Bottom Skid Only
Ambient/SCCR Options
0
– Std Ambient, Std Interrupt
3
– Std Ambient, High Interrupt
6
– Low Ambient, Std Interrupt
9
– Low Ambient, High Interrupt
Not Used
Electrical Options
0
– Single Point Power, Terminal Block
1
– Single Point Power,
Non-Fused
Disconnect
Refrigeration Circuit Options*
M
– Multiple Refrigeration Circuit
S
– Single Refrigeration Circuit
Revision Level
–
– Current Revision Level
y
l
p
p
u
S
r
e
w
o
P
1
– 575-3-60
2
– 380-3-60
5
– 208/230-3-60
6
– 460-3-60
9
– 380/415-3-50
Condenser Coil/Low Sound Options
4
– MCHX, No Sound Treatment
5
– E-coat, MCHX, No Sound Treatment
C
– MCHX, Low Sound Fan(s)
D
– E-coat MCHX, Low Sound Fan(s)
Unit Size
D
– Bottom Skid, Security Grilles/Hail Guards
J
– Bottom Skid, Top Crate, Bag
N
– Bottom Skid, Top Crate, Bag,
Security Grilles/Hail Guards
018
040
085
020
050
095
030
065
035
075
060
115
130
Not Used
LEGEND
*09DPS units available in sizes 018-030. 09DPM units
available in sizes 035-130.
Quality Assurance
Certified to ISO 9001:2000
MCHX —
Microchannel Heat Exchanger
a09-575
Fig. 1 — Model Number Nomenclature