F96CTN and G96CTN (Series A): Installation, Start-up, Operating, Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
52
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
Unit Size:
0801714
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2-3
SW2-2
SW2-1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1085
1095
1095
1100
1100
1095
1090
1095
1085
1080
CF Switches
SW3-3
SW3-2
SW3-1
Low Clg Default:
OFF
OFF
OFF
550
550
545
535
520
See note 4
Cooling Airflow (SW2)
Low Cooling Airflow (SW3)
OFF
OFF
ON
550
550
545
535
520
See note 4
OFF
ON
OFF
705
710
710
710
700
See note 4
OFF
ON
ON
885
900
910
910
910
905
900
895
885
875
ON
OFF
OFF
1085
1095
1095
1100
1100
1095
1090
1095
1085
1080
ON
OFF
ON
1255
1265
1265
1270
1275
1275
1255
1220
1190
1160
ON
ON
OFF
1420
1410
1375
1345
1310
1280
1255
1220
1190
1160
ON
ON
ON
1420
1410
1375
1345
1310
1280
1255
1220
1190
1160
Maximum Clg Airflow
2
1445
1410
1375
1345
1310
1275
1255
1220
1190
1160
CF Switches
SW3-3
SW3-2
SW3-1
Cont. Fan Default:
OFF
OFF
OFF
550
550
545
535
520
See note 4
Continuous Fan Airflow (SW3)
OFF
OFF
ON
430
410
390
370
350
See note 4
OFF
ON
OFF
485
475
455
440
420
See note 4
OFF
ON
ON
550
550
545
535
520
See note 4
ON
OFF
OFF
550
550
545
535
520
See note 4
ON
OFF
ON
550
550
545
535
520
See note 4
ON
ON
OFF
550
550
545
535
520
See note 4
ON
ON
ON
550
550
545
535
520
See note 4
Heating (SW1)
High Heat Airflow
3
1235
1245
1250
1255
1255
1260
1255
1220
1190
1160
Low Heat Airflow
3
1005
1010
1015
1015
1020
1000
995
990
980
970
Unit size:
0802120
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2-3
SW2-2
SW2-1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1745
1755
1755
1760
1755
1750
1745
1725
1705
1685
CF Switches
SW3-3
SW3-2
SW3-1
Low Clg Default:
OFF
OFF
OFF
700
710
750
725
750
See note 4
Cooling Airflow (SW2)
Low Cooling Airflow (SW3)
OFF
OFF
ON
700
710
750
725
750
See note 4
OFF
ON
OFF
830
860
870
890
960
See note 4
OFF
ON
ON
1045
1045
1060
1070
1070
1070
1095
1090
1080
1070
ON
OFF
OFF
1215
1220
1245
1240
1235
1235
1225
1220
1235
1235
ON
OFF
ON
1370
1370
1390
1390
1400
1395
1400
1390
1390
1385
ON
ON
OFF
1745
1755
1755
1760
1755
1750
1745
1725
1705
1685
ON
ON
ON
1745
1755
1755
1760
1755
1750
1745
1725
1705
1685
Maximum Clg Airflow
2
1920
1920
1945
1945
1945
1960
1950
1940
1915
1900
CF Switches
SW3-3
SW3-2
SW3-1
Cont. Fan Default:
OFF
OFF
OFF
700
710
750
725
750
See note 4
Continuous Fan Airflow (SW3)
OFF
OFF
ON
700
710
750
725
750
See note 4
OFF
ON
OFF
830
860
870
890
960
See note 4
OFF
ON
ON
1045
1045
1060
1070
1070
1070
1095
1090
1080
1070
ON
OFF
OFF
1215
1220
1245
1240
1235
1235
1225
1220
1235
1235
ON
OFF
ON
1215
1220
1245
1240
1235
1235
1225
1220
1235
1235
ON
ON
OFF
1215
1220
1245
1240
1235
1235
1225
1220
1235
1235
ON
ON
ON
1215
1220
1245
1240
1235
1235
1225
1220
1235
1235
Heating (SW1)
High Heat Airflow
3
1340
1355
1370
1385
1380
1385
1400
1400
1385
1380
Low Heat Airflow
3
1080
1115
1115
1120
1125
1135
1125
1120
1125
1110
Table 17 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
with Filter) (Continued)