Carrier Comfort 25HCD4 Скачать руководство пользователя страница 2

2

MODEL NUMBER NOMENCLATURE

1

2

3

4

5

6

7

8

9

10

11

12

13

N

N

A

A

A/N

N

N

N

A/N

A/N

A/N

N

N

2

5

H

C

D

4

3

6

A

0

0

3

0

Product

Series

Product

Family

Tier

Major

Series

SEER

Cooling

Capacity

Grille

Variations

Open

Open

Voltage

Minor

Series

25 = HP

H = RES HP C=Comfort D = Puron

4=14 SEER

A=Dense Grille

W=Wide Grille

0=Not

Defined

0=Not

Defined

3=208/230---1 0, 1, 2...

the environmentally sound refrigerant

This product has been designed and manufactured to

meet Energy Star

criteria for energy efficiency when

matched with appropriate coil components. However,

proper refrigerant charge and proper air flow are critical

to achieve rated capacity and efficiency. Installation of

this product should follow all manufacturing refrigerant

charging and air flow instructions.

Failure to confirm

proper charge and air flow may reduce energy

efficiency and shorten equipment life.

Use of the AHRI Certified
TM Mark indicates a
manufacturer’s  
participation in the 
program For verification 
of certification for individual 
products, go to 
www.ahridirectory.org. 

STANDARD FEATURES

Feature

18

24

30

36

42

48

60

Puron Refrigerant

X

X

X

X

X

X

X

Maximum SEER Rating

14.0

14.0

14.0

14.0

14.0

14.0

14.0

Scroll Compressor

X

X

X

X

X

X

X

Field Installed Filter Drier

X

X

X

X

X

X

X

Front Seating Service Valves

X

X

X

X

X

X

X

Internal Pressure Relief Valve

X

X

X

X

X

X

X

Internal Thermal Overload

X

X

X

X

X

X

X

Long Line capability

X

X

X

X

X

X

X

Low Ambient capability with Kit

X

X

X

X

X

X

X

Suction Line Accumulator

X

X

X

X

X

X

X

High Pressure Switch

X

X

X

X

X

X

X

Loss of Charge Switch

X

X

X

X

X

X

X

X = Standard

25H

C

D

4

Содержание Comfort 25HCD4

Страница 1: ...ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 14 SEER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 69 dB...

Страница 2: ...all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life Use of the AHRI Certified TM Mark...

Страница 3: ...Cooling Capacity Losses Puronr Refrigerant 1 Stage Heat Pump Applications Unit Nominal Size Btuh Maximum Liquid Line Diameters In OD Vapor Line Diameters In OD Cooling Capacity Loss Total Equivalent...

Страница 4: ...0 250 250 250 250 24000 HP with Puron 3 8 250 250 250 250 250 250 250 30000 HP with Puron 3 8 250 250 250 250 250 250 250 36000 HP with Puron 3 8 250 250 250 250 250 250 250 42000 HP with Puron 3 8 25...

Страница 5: ...X X X X X KSASH2101COP SOUND BLKT KIT X KSASF0101AAA SPRT FEET KIT X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X KSATX0201PUR TXV KIT X X X KSATX0301PUR TXV KIT X X KSATX0501PUR TXV KIT X x Acce...

Страница 6: ...mproves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all c...

Страница 7: ...allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump ins...

Страница 8: ...TE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection Complies...

Страница 9: ...9 DIMENSIONS ENGLISH 25HCD4...

Страница 10: ...10 DIMENSIONS SI 25HCD4...

Страница 11: ...Y MBTUH 25HCD424A30 FB4CNF030 25HCD442A30 FB4CNF048 25HCD430A30 FB4CNF030 25HCD448A30 FB4CNF060 25HCD436A30 FB4CNF036 25HCD460A30 FX4DNF061 25HCD418A30 FB4CNF018 23 3 17 8 12 2 6 7 1 1 4 4 10 0 15 6 2...

Страница 12: ...2 24 609 6 Service 6 152 4 12 304 8 24 609 6 Service 24 609 6 Service 24 609 6 Service Note Numbers in mm 18 457 2 18 457 2 12 304 8 IMPORTANT When installing multiple units in an alcove roof well or...

Страница 13: ...TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD436 31 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD442 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD448 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25H...

Страница 14: ...r fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be c...

Страница 15: ...rconnecting refrigerant tube lengths greater than 80 ft 23 4 m and or elevation differences between indoor and outdoor units greater than 20 ft 6 1 m consult Residential Piping and Longline Guideline...

Страница 16: ...rp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 02 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 25HC...

Отзывы: