fittings be used on the condensate pan. Do not over--tighten. Finger
tighten plus 1--1/2 turns. Be sure to install plastic plug in unused

condensate drain fitting.

NOTE

: If unit is located in or above a living space where damage

may result from condensate overflow, a field--supplied, external
condensate pan should be installed under the entire unit, and a
secondary condensate line (with appropriate trap) should be run
from unit into pan. Any condensate in this external condensate pan
should be drained to a noticeable place. As an alternative to using
an external condensate pan, some localities may allow the running
of a separate 3/4” (19 mm) condensate line (with appropriate trap)
to a place where condensate will be noticeable. The owner of the
structure must be informed that when condensate flows from the
secondary drain or external condensate pan, the unit requires
servicing or water damage will occur. To further protect against
water damage, install a float switch to shut the unit off if the water
in the secondary pan gets too high.
Install traps in condensate lines as close to coil as possible. See Fig.

8. Make sure that outlet of each trap is below its connection to
condensate pan to prevent condensate from overflowing drain pan.

Prime all traps, test for leaks, and insulate traps and lines if located

above a living area. Consult local codes for additional restrictions
or precautions.

Humidifier Application

When installing a humidifier in a system which contains an N--coil,
consideration must be given to location of coil slabs. See Fig. 9.

1. Care must be taken to prevent damage of N--coil when at-

taching humidifier to coil casing or plenum.

2. The models marked with an * in Table 1 are shipped with a

Caution Label to be applied to plenum to indicate slab loca-

tion. See Fig. 7. When these coils are removed from their
casing and applied directly into the plenum, affix this Cau-
tion Label to the right side of the plenum enclosure. This is

needed only in cases where the humidifier is not installed
with original equipment. Label will alert future service and

installation technicians about coil slab location.

3. Ensure that humidifier has adequate airflow.

3" (76)

A08339

Fig. 8 -- Condensate Trap

Supply

Evaporator

N-Coil

Upflow

Furnace

A05414

Fig. 9 -- Installation of Humidifier in System with N--Coil

Field-Supplied
    Plenum

  Field
Support
  Shelf

Furnace

3

″ 

(76) min.

"A"

"B"

A08340

Fig. 10 -- Transition Required for Overhang Except for

Transition Coils

Copyright 2008 CAC / BDP

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 06/08

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: IM---CNPVP---02

Replaces: IM--- CNPVP--- 01

CNP

VP

/CNR

VP

Содержание CNPVP, CNRVP

Страница 1: ...G signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation IMPORTANT Nitrogen can leak out through the hole that the needle pierced in the plugs This does not indicate ...

Страница 2: ...e coil or lack of air to a slab in the coil It is recommended that on this type of application a field supplied adapter be placed between the coil and furnace to allow air to distribute properly between all slabs of the coil To install cased coils in upflow applications follow the instructions below Upflow Cased Coil Installation To install cased coils in downflow applications follow the instructi...

Страница 3: ...ock off plates at casing base by removing 2 screws per plate from side of casing See Fig 3 Block Off Plates A05412 Fig 3 Block Off Plate Removal TRANSITION MODEL COILS APPLIED CENTERED OVER NARROW FURNACE 1 There is no transition required for this application 2 Remove coil from packaging and place on top of furnace with 1 5 8 41 mm overhang on both sides See Fig 4 Alternative A 3 Continue with nor...

Страница 4: ...on en tirely on left side as in Fig 4 Alternative C Mark location of gas furnace flange on coil casing Remove coil from top of furnace Using tin snips make a notch in rail large enough to allow clearance for gas flow furnace flange 2 Place coil on top of gas furnace Make sure coil is shifted completely to left side and notch is sufficient so coil rests on top of furnace cabinet 3 Prepare and insta...

Страница 5: ...ctions The coil can be connected to outdoor units using accessory tubing packages or field supplied tubing of refrigerant grade Always evacuate tubing and reclaim refrigerant when making connections or flaring tubing Leak check connections before insulating entire suction line SUCTION LINE Suction line is designed for field sweat connection Line is plugged to keep out moisture and dirt Remove thes...

Страница 6: ...t for leaks and insulate traps and lines if located above a living area Consult local codes for additional restrictions or precautions Humidifier Application When installing a humidifier in a system which contains an N coil consideration must be given to location of coil slabs See Fig 9 1 Care must be taken to prevent damage of N coil when at taching humidifier to coil casing or plenum 2 The model...

Отзывы: