![Carrier C302 NPR Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/carrier/c302-npr/c302-npr_operating-instructions-manual_2562686033.webp)
29
Model C302 NPR
Operating Procedures
Draining Product From the
Freezing Cylinders
Step 1
Press the BEATER (- - -) key. This will allow beater
operation to push the product from the freezing
cylinder. Open the draw valve and drain the product
from the machine.
Figure 35
Step 2
When all the product has been drained from the
freezing cylinder, close the draw valve and press the
OFF (<- -) key. Discard this product.
Figure 36
Step 3
Repeat Steps 1 and 2 for the other freezing
cylinders.
Rinsing
Note:
The following instructions are for one pair of
freezing cylinders under an LCD. After the
instructions are complete, repeat for the two freezing
cylinders on the other side of the machine under the
other LCD.
Step 1
To place the left cylinder in the RINSE mode, press
the MENU (SEL) key. Move the cursor by pressing
the AUTO (- ->) key until the third line indicates
RINSE / SANITIZE.
OPERATOR MENU
A B C D E F G H I
RINSE / SANITIZE
<- - - ->
SEL
Step 2
Press the MENU (SEL) key. Move the cursor under
“RINSE” by pressing the OFF (<- -) key twice.
RINSE / SANITIZE
RINSE
SANITIZE
EXIT
- - - -
<- - - ->
SEL
Step 3
Pressing the MENU (SEL) key will give you the
option for rinsing the left freezing cylinder. Move the
cursor under the word “YES”. Pressing the MENU
(SEL) key at this time will start the beater motor and
deliver water and CO
2
to the left cylinder.
RINSE
LEFT
SIDE
YES
NO
- - -
<- - - ->
SEL
Step 4
Allow the rinse water to flow into the cylinder until it
is approximately 2/3 full. With a pail under the door
spout, open the draw valve and drain the rinse
water.
Repeat this procedure
until the rinse water
being drawn is clear.