Sanitizing
IMPORTANT:
If a unit is sanitized, and will not be
used for an extended period of time, clean water
should be used to flush all sanitizer from the lines.
Remove the water from all the lines and components
prior to storage of the unit. Upon return to service,
the unit must be sanitized prior to use.
Note:
The following instructions are for one side of
the unit. Each side consists of two freezing cylinders
each, identified on the corresponding LCD as “left”
(L) and “right” (R).
Step 1
Open the lighted display door. Place the control
switch in the ON position.
Figure 21
Step 2
Prepare a pail of approved 100 PPM sanitizing
solution (examples: 2-1/2 gal. [9.5 liters] of Kay-5
R
or 2 gal. [7.6 liters] of Stera-Sheen
R
). USE WARM
WATER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Important:
Make sure the sanitizer is completely
dissolved.
Step 3
Using an empty bag of syrup, cut the syrup line
connector from the end of the bag.
Figure 22
Step 4
Connect the syrup line to the syrup line connector
that was cut from the syrup bag.